Compare commits
24
Commits
main
..
b07ccc2628
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
b07ccc2628 | ||
|
|
af161f736e | ||
|
|
12327157f0 | ||
|
|
91be39cd87 | ||
|
|
9287ca9d9a | ||
|
|
c4a78d1995 | ||
|
|
a2ddd42cc9 | ||
|
|
5331561c48 | ||
|
|
0ca0e41871 | ||
|
|
992feb3bee | ||
|
|
e8c232322d | ||
|
|
15b56b4af3 | ||
|
|
5ede5bccc6 | ||
|
|
11022ec42a | ||
|
|
7f158c2e59 | ||
|
|
6e34032e1e | ||
|
|
6b748a0fe7 | ||
|
|
c3126a1421 | ||
|
|
270ef18bd4 | ||
|
|
3510db84ff | ||
|
|
62e7b2d341 | ||
|
|
753c3756ed | ||
|
|
7fc159a470 | ||
|
|
365f7f2c55 |
No files matched your search
+3
-4
@@ -1,14 +1,13 @@
|
||||
text_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Anlagenzustand"
|
||||
id: ${lower_name}_Anlagenzustand
|
||||
name: "${name} Anlagenzustand"
|
||||
id: ${name}_Anlagenzustand
|
||||
register_type: read
|
||||
address: 4000
|
||||
raw_encode: HEXBYTES
|
||||
lambda: |-
|
||||
uint16_t value = modbus::helpers::word_from_hex_str(x, 0);
|
||||
uint16_t value = modbus_controller::word_from_hex_str(x, 0);
|
||||
switch (value) {
|
||||
case 0: return std::string("Dauerlast");
|
||||
case 1: return std::string("Brauchwasser");
|
||||
|
||||
+12
-20
@@ -1,9 +1,8 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Fuellstand im Pelletsbehaelter"
|
||||
id: ${lower_name}_Fuellstand_im_Pelletsbehaelter
|
||||
name: "${name} Fuellstand im Pelletsbehaelter"
|
||||
id: ${name}_Fuellstand_im_Pelletsbehaelter
|
||||
register_type: read
|
||||
address: 21
|
||||
unit_of_measurement: "%"
|
||||
@@ -14,9 +13,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Resetierbarer kg-Zaehler"
|
||||
id: ${lower_name}_Resetierbarer_kg_Zaehler
|
||||
name: "${name} Resetierbarer kg-Zaehler"
|
||||
id: ${name}_Resetierbarer_kg_Zaehler
|
||||
register_type: read
|
||||
address: 81
|
||||
unit_of_measurement: "kg"
|
||||
@@ -24,9 +22,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Resetierbarer t-Zaehler"
|
||||
id: ${lower_name}_Resetierbarer_t_Zaehler
|
||||
name: "${name} Resetierbarer t-Zaehler"
|
||||
id: ${name}_Resetierbarer_t_Zaehler
|
||||
register_type: read
|
||||
address: 82
|
||||
unit_of_measurement: "t"
|
||||
@@ -34,24 +31,20 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Pelletverbrauch Gesamt"
|
||||
id: ${lower_name}_Pelletverbrauch_Gesamt
|
||||
name: "${name} Pelletverbrauch Gesamt"
|
||||
id: ${name}_Pelletverbrauch_Gesamt
|
||||
register_type: read
|
||||
address: 83
|
||||
unit_of_measurement: "kg"
|
||||
state_class: total_increasing
|
||||
device_class: weight
|
||||
unit_of_measurement: "t"
|
||||
accuracy_decimals: 1
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 100
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Pelletlager Restbestand"
|
||||
id: ${lower_name}_Pelletlager_Restbestand
|
||||
name: "${name} Pelletlager Restbestand"
|
||||
id: ${name}_Pelletlager_Restbestand
|
||||
register_type: holding
|
||||
address: 319
|
||||
unit_of_measurement: "t"
|
||||
@@ -59,4 +52,3 @@ sensor:
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
+11
-20
@@ -1,23 +1,19 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Temperatur oben"
|
||||
id: ${lower_name}_Boiler_1_Temperatur_oben
|
||||
name: "${boiler1_name} Temperatur oben"
|
||||
id: ${name}_Boiler_1_Temperatur_oben
|
||||
register_type: read
|
||||
address: 1630
|
||||
unit_of_measurement: "°C"
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
value_type: S_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Pumpe Ansteuerung"
|
||||
id: ${lower_name}_Boiler_1_Pumpe_Ansteuerung
|
||||
name: "${boiler1_name} Pumpe Ansteuerung"
|
||||
id: ${name}_Boiler_1_Pumpe_Ansteuerung
|
||||
register_type: read
|
||||
address: 1632
|
||||
unit_of_measurement: "%"
|
||||
@@ -26,11 +22,9 @@ sensor:
|
||||
number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Boilertemperatur"
|
||||
id: ${lower_name}_Boiler_1_Gewuenschte_Boilertemperatur
|
||||
name: "${boiler1_name} Gewünschte Boilertemperatur"
|
||||
id: ${name}_Boiler_1_Gewuenschte_Boilertemperatur
|
||||
address: 1631
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -39,11 +33,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Nachladen, wenn Boilertemperatur unter"
|
||||
id: ${lower_name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
|
||||
name: "${boiler1_name} Nachladen, wenn Boilertemperatur unter"
|
||||
id: ${name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
|
||||
address: 1632
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -52,11 +44,10 @@ number:
|
||||
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
device_id: ${device_id}
|
||||
name: "Pumpe Ansteuerung AN AUS"
|
||||
id: ${lower_name}_Boiler_1_Pumpe_Ansteuerung_AN_AUS
|
||||
name: "${boiler1_name} Pumpe Ansteuerung AN AUS"
|
||||
id: ${name}_Boiler_1_Pumpe_Ansteuerung_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${lower_name}_Boiler_1_Pumpe_Ansteuerung).state > 0) {
|
||||
if (id(${name}_Boiler_1_Pumpe_Ansteuerung).state > 0) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
|
||||
+15
-22
@@ -1,16 +1,13 @@
|
||||
# To-do: Implementierung der Fehlermeldungen ohne der Kopie
|
||||
|
||||
text_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Fehler 1"
|
||||
id: ${lower_name}_Fehler_1
|
||||
name: "${name} Fehler 1"
|
||||
id: ${name}_Fehler_1
|
||||
register_type: read
|
||||
address: 3000
|
||||
raw_encode: HEXBYTES
|
||||
lambda: |-
|
||||
uint16_t value = modbus::helpers::word_from_hex_str(x, 0);
|
||||
uint16_t value = modbus_controller::word_from_hex_str(x, 0);
|
||||
switch (value) {
|
||||
case 0: return std::string("STB gefallen oder NOT-AUS betätigt");
|
||||
case 1: return std::string("Kesseltemperaturfühler fehlerhaft");
|
||||
@@ -448,14 +445,13 @@ text_sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Fehler 2"
|
||||
id: ${lower_name}_Fehler_2
|
||||
name: "${name} Fehler 2"
|
||||
id: ${name}_Fehler_2
|
||||
register_type: read
|
||||
address: 3001
|
||||
raw_encode: HEXBYTES
|
||||
lambda: |-
|
||||
uint16_t value = modbus::helpers::word_from_hex_str(x, 0);
|
||||
uint16_t value = modbus_controller::word_from_hex_str(x, 0);
|
||||
switch (value) {
|
||||
case 0: return std::string("STB gefallen oder NOT-AUS betätigt");
|
||||
case 1: return std::string("Kesseltemperaturfühler fehlerhaft");
|
||||
@@ -893,14 +889,13 @@ text_sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Fehler 3"
|
||||
id: ${lower_name}_Fehler_3
|
||||
name: "${name} Fehler 3"
|
||||
id: ${name}_Fehler_3
|
||||
register_type: read
|
||||
address: 3002
|
||||
raw_encode: HEXBYTES
|
||||
lambda: |-
|
||||
uint16_t value = modbus::helpers::word_from_hex_str(x, 0);
|
||||
uint16_t value = modbus_controller::word_from_hex_str(x, 0);
|
||||
switch (value) {
|
||||
case 0: return std::string("STB gefallen oder NOT-AUS betätigt");
|
||||
case 1: return std::string("Kesseltemperaturfühler fehlerhaft");
|
||||
@@ -1338,14 +1333,13 @@ text_sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Fehler 4"
|
||||
id: ${lower_name}_Fehler_4
|
||||
name: "${name} Fehler 4"
|
||||
id: ${name}_Fehler_4
|
||||
register_type: read
|
||||
address: 3003
|
||||
raw_encode: HEXBYTES
|
||||
lambda: |-
|
||||
uint16_t value = modbus::helpers::word_from_hex_str(x, 0);
|
||||
uint16_t value = modbus_controller::word_from_hex_str(x, 0);
|
||||
switch (value) {
|
||||
case 0: return std::string("STB gefallen oder NOT-AUS betätigt");
|
||||
case 1: return std::string("Kesseltemperaturfühler fehlerhaft");
|
||||
@@ -1783,14 +1777,13 @@ text_sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Fehler 5"
|
||||
id: ${lower_name}_Fehler_5
|
||||
name: "${name} Fehler 5"
|
||||
id: ${name}_Fehler_5
|
||||
register_type: read
|
||||
address: 3004
|
||||
raw_encode: HEXBYTES
|
||||
lambda: |-
|
||||
uint16_t value = modbus::helpers::word_from_hex_str(x, 0);
|
||||
uint16_t value = modbus_controller::word_from_hex_str(x, 0);
|
||||
switch (value) {
|
||||
case 0: return std::string("STB gefallen oder NOT-AUS betätigt");
|
||||
case 1: return std::string("Kesseltemperaturfühler fehlerhaft");
|
||||
|
||||
+30
-57
@@ -1,9 +1,8 @@
|
||||
select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Betriebsart"
|
||||
id: ${lower_name}_HK1_Betriebsart
|
||||
name: "${hk1_name} - Betriebsart"
|
||||
id: ${name}_HK1_Betriebsart
|
||||
address: 8046
|
||||
value_type: U_WORD
|
||||
optionsmap:
|
||||
@@ -17,23 +16,19 @@ select:
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Vorlauf-Isttemperatur"
|
||||
id: ${lower_name}_HK1_Vorlauf_Isttemperatur
|
||||
name: "${hk1_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1030 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
value_type: S_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Vorlauf-Solltemperatur"
|
||||
id: ${lower_name}_HK1_Vorlauf_Solltemperatur
|
||||
name: "${hk1_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1031 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -43,9 +38,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Raumtemperatur"
|
||||
id: ${lower_name}_HK1_Raumtemperatur
|
||||
name: "${hk1_name} - Raumtemperatur"
|
||||
id: ${name}_HK1_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1032 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -56,9 +50,8 @@ sensor:
|
||||
binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Pumpe AN AUS"
|
||||
id: ${lower_name}_HK1_Pumpe_AN_AUS
|
||||
name: "${hk1_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK1_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
address: 1029
|
||||
|
||||
@@ -66,11 +59,9 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${lower_name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1032
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -80,11 +71,9 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${lower_name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1031
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -93,11 +82,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${lower_name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
name: "${hk1_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1039
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -106,11 +93,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${lower_name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
name: "${hk1_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1033
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -119,11 +104,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
name: "${hk1_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
address: 1035
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -132,11 +115,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
name: "${hk1_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
address: 1040
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -145,11 +126,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1036
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -158,11 +137,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1037
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -171,11 +148,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Frostschutztemperatur"
|
||||
id: ${lower_name}_HK1_Frostschutztemperatur
|
||||
name: "${hk1_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK1_Frostschutztemperatur
|
||||
address: 1038
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -184,11 +159,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${lower_name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
name: "${hk1_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1047
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
min_value: 60
|
||||
|
||||
+30
-57
@@ -1,9 +1,8 @@
|
||||
select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Betriebsart"
|
||||
id: ${lower_name}_HK2_Betriebsart
|
||||
name: "${hk2_name} - Betriebsart"
|
||||
id: ${name}_HK2_Betriebsart
|
||||
address: 8047
|
||||
value_type: U_WORD
|
||||
optionsmap:
|
||||
@@ -17,23 +16,19 @@ select:
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Vorlauf-Isttemperatur"
|
||||
id: ${lower_name}_HK2_Vorlauf_Isttemperatur
|
||||
name: "${hk2_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1060 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
value_type: S_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Vorlauf-Solltemperatur"
|
||||
id: ${lower_name}_HK2_Vorlauf_Solltemperatur
|
||||
name: "${hk2_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1061 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -43,9 +38,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Raumtemperatur"
|
||||
id: ${lower_name}_HK2_Raumtemperatur
|
||||
name: "${hk2_name} - Raumtemperatur"
|
||||
id: ${name}_HK2_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1062 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -56,9 +50,8 @@ sensor:
|
||||
binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Pumpe AN AUS"
|
||||
id: ${lower_name}_HK2_Pumpe_AN_AUS
|
||||
name: "${hk2_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK2_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
address: 1059
|
||||
|
||||
@@ -66,11 +59,9 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${lower_name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1061
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -80,11 +71,9 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${lower_name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1062
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -93,11 +82,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${lower_name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
name: "${hk2_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1063
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -106,11 +93,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${lower_name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
name: "${hk2_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1069
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -119,11 +104,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
name: "${hk2_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
address: 1065
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -132,11 +115,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
name: "${hk2_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
address: 1070
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -145,11 +126,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1066
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -158,11 +137,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1067
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -171,11 +148,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Frostschutztemperatur"
|
||||
id: ${lower_name}_HK2_Frostschutztemperatur
|
||||
name: "${hk2_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK2_Frostschutztemperatur
|
||||
address: 1068
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -184,11 +159,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${lower_name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
name: "${hk2_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1078
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
min_value: 60
|
||||
|
||||
+30
-57
@@ -1,9 +1,8 @@
|
||||
select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Betriebsart"
|
||||
id: ${lower_name}_HK3_Betriebsart
|
||||
name: "${hk3_name} - Betriebsart"
|
||||
id: ${name}_HK3_Betriebsart
|
||||
address: 8048
|
||||
value_type: U_WORD
|
||||
optionsmap:
|
||||
@@ -17,23 +16,19 @@ select:
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Vorlauf-Isttemperatur"
|
||||
id: ${lower_name}_HK3_Vorlauf_Isttemperatur
|
||||
name: "${hk3_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK3_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1090 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
value_type: S_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Vorlauf-Solltemperatur"
|
||||
id: ${lower_name}_HK3_Vorlauf_Solltemperatur
|
||||
name: "${hk3_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK3_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1091 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -43,9 +38,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Raumtemperatur"
|
||||
id: ${lower_name}_HK3_Raumtemperatur
|
||||
name: "${hk3_name} - Raumtemperatur"
|
||||
id: ${name}_HK3_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1092 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -56,9 +50,8 @@ sensor:
|
||||
binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Pumpe AN AUS"
|
||||
id: ${lower_name}_HK3_Pumpe_AN_AUS
|
||||
name: "${hk3_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK3_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
address: 1090
|
||||
|
||||
@@ -66,11 +59,9 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${lower_name}_HK3_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
name: "${hk3_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK3_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1091
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -80,11 +71,9 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${lower_name}_HK3_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
name: "${hk3_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK3_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1092
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -93,11 +82,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${lower_name}_HK3_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
name: "${hk3_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK3_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1093
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -106,11 +93,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${lower_name}_HK3_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
name: "${hk3_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK3_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1099
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -119,11 +104,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${lower_name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
name: "${hk3_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
address: 1095
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -132,11 +115,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${lower_name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
name: "${hk3_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
address: 1100
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -145,11 +126,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${lower_name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
name: "${hk3_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1096
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -158,11 +137,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${lower_name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
name: "${hk3_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1097
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -171,11 +148,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Frostschutztemperatur"
|
||||
id: ${lower_name}_HK3_Frostschutztemperatur
|
||||
name: "${hk3_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK3_Frostschutztemperatur
|
||||
address: 1098
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -184,11 +159,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${lower_name}_HK3_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
name: "${hk3_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK3_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1105
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
min_value: 60
|
||||
|
||||
+30
-57
@@ -1,9 +1,8 @@
|
||||
select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Betriebsart"
|
||||
id: ${lower_name}_HK4_Betriebsart
|
||||
name: "${hk4_name} - Betriebsart"
|
||||
id: ${name}_HK4_Betriebsart
|
||||
address: 8049
|
||||
value_type: U_WORD
|
||||
optionsmap:
|
||||
@@ -17,23 +16,19 @@ select:
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Vorlauf-Isttemperatur"
|
||||
id: ${lower_name}_HK4_Vorlauf_Isttemperatur
|
||||
name: "${hk4_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK4_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1120 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
value_type: S_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Vorlauf-Solltemperatur"
|
||||
id: ${lower_name}_HK4_Vorlauf_Solltemperatur
|
||||
name: "${hk4_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK4_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1121 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -43,9 +38,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Raumtemperatur"
|
||||
id: ${lower_name}_HK4_Raumtemperatur
|
||||
name: "${hk4_name} - Raumtemperatur"
|
||||
id: ${name}_HK4_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1122 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -56,9 +50,8 @@ sensor:
|
||||
binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Pumpe AN AUS"
|
||||
id: ${lower_name}_HK4_Pumpe_AN_AUS
|
||||
name: "${hk4_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK4_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
address: 1120
|
||||
|
||||
@@ -66,11 +59,9 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${lower_name}_HK4_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK4_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1121
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -80,11 +71,9 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${lower_name}_HK4_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK4_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1122
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -93,11 +82,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${lower_name}_HK4_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
name: "${hk4_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK4_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1123
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -106,11 +93,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${lower_name}_HK4_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
name: "${hk4_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK4_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1129
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -119,11 +104,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
name: "${hk4_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
address: 1125
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -132,11 +115,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
name: "${hk4_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
address: 1130
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -145,11 +126,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1126
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -158,11 +137,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1127
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -171,11 +148,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Frostschutztemperatur"
|
||||
id: ${lower_name}_HK4_Frostschutztemperatur
|
||||
name: "${hk4_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK4_Frostschutztemperatur
|
||||
address: 1128
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -184,11 +159,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${lower_name}_HK4_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
name: "${hk4_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK4_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1135
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
min_value: 60
|
||||
|
||||
+30
-57
@@ -1,9 +1,8 @@
|
||||
select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Betriebsart"
|
||||
id: ${lower_name}_HK5_Betriebsart
|
||||
name: "${hk5_name} - Betriebsart"
|
||||
id: ${name}_HK5_Betriebsart
|
||||
address: 8050
|
||||
value_type: U_WORD
|
||||
optionsmap:
|
||||
@@ -17,23 +16,19 @@ select:
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Vorlauf-Isttemperatur"
|
||||
id: ${lower_name}_HK5_Vorlauf_Isttemperatur
|
||||
name: "${hk5_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK5_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1150 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
value_type: S_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Vorlauf-Solltemperatur"
|
||||
id: ${lower_name}_HK5_Vorlauf_Solltemperatur
|
||||
name: "${hk5_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK5_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1151 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -43,9 +38,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Raumtemperatur"
|
||||
id: ${lower_name}_HK5_Raumtemperatur
|
||||
name: "${hk5_name} - Raumtemperatur"
|
||||
id: ${name}_HK5_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1152 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -56,9 +50,8 @@ sensor:
|
||||
binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Pumpe AN AUS"
|
||||
id: ${lower_name}_HK5_Pumpe_AN_AUS
|
||||
name: "${hk5_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK5_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
address: 1150
|
||||
|
||||
@@ -66,11 +59,9 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${lower_name}_HK5_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
name: "${hk5_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK5_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1151
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -80,11 +71,9 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${lower_name}_HK5_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
name: "${hk5_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK5_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1152
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -93,11 +82,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${lower_name}_HK5_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
name: "${hk5_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK5_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1153
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -106,11 +93,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${lower_name}_HK5_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
name: "${hk5_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK5_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1159
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -119,11 +104,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${lower_name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
name: "${hk5_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
address: 1155
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -132,11 +115,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${lower_name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
name: "${hk5_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
address: 1160
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -145,11 +126,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${lower_name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
name: "${hk5_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1156
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -158,11 +137,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${lower_name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
name: "${hk5_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1157
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -171,11 +148,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Frostschutztemperatur"
|
||||
id: ${lower_name}_HK5_Frostschutztemperatur
|
||||
name: "${hk5_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK5_Frostschutztemperatur
|
||||
address: 1158
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
@@ -184,11 +159,9 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${lower_name}_HK5_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
name: "${hk5_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK5_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1165
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
min_value: 60
|
||||
|
||||
+64
-87
@@ -1,14 +1,13 @@
|
||||
text_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Kesselzustand"
|
||||
id: ${lower_name}_Kesselzustand
|
||||
name: "${name} Kesselzustand"
|
||||
id: ${name}_Kesselzustand
|
||||
register_type: read
|
||||
address: 4001
|
||||
raw_encode: HEXBYTES
|
||||
lambda: |-
|
||||
uint16_t value = modbus::helpers::word_from_hex_str(x, 0);
|
||||
uint16_t value = modbus_controller::word_from_hex_str(x, 0);
|
||||
switch (value) {
|
||||
case 0: return std::string("STÖRUNG");
|
||||
case 1: return std::string("Kessel Aus");
|
||||
@@ -100,9 +99,8 @@ text_sensor:
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Kesseltemperatur"
|
||||
id: ${lower_name}_Kesseltemperatur
|
||||
name: "${name} Kesseltemperatur"
|
||||
id: ${name}_Kesseltemperatur
|
||||
register_type: read
|
||||
address: 0
|
||||
unit_of_measurement: "°C"
|
||||
@@ -112,9 +110,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Abgastemperatur"
|
||||
id: ${lower_name}_Abgastemperatur
|
||||
name: "${name} Abgastemperatur"
|
||||
id: ${name}_Abgastemperatur
|
||||
register_type: read
|
||||
address: 1
|
||||
unit_of_measurement: "°C"
|
||||
@@ -122,9 +119,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Saugzug - Ansteuerung"
|
||||
id: ${lower_name}_Saugzug_Ansteuerung
|
||||
name: "${name} Saugzug - Ansteuerung"
|
||||
id: ${name}_Saugzug_Ansteuerung
|
||||
register_type: read
|
||||
address: 13
|
||||
unit_of_measurement: "%"
|
||||
@@ -132,9 +128,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Saugzugdrehzahl"
|
||||
id: ${lower_name}_Saugzugdrehzahl
|
||||
name: "${name} Saugzugdrehzahl"
|
||||
id: ${name}_Saugzugdrehzahl
|
||||
register_type: read
|
||||
address: 6
|
||||
unit_of_measurement: "rpm"
|
||||
@@ -142,9 +137,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Sauerstoffregler"
|
||||
id: ${lower_name}_Sauerstoffregler
|
||||
name: "${name} Sauerstoffregler"
|
||||
id: ${name}_Sauerstoffregler
|
||||
register_type: read
|
||||
address: 16
|
||||
unit_of_measurement: "%"
|
||||
@@ -152,9 +146,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Restsauerstoffgehalt"
|
||||
id: ${lower_name}_Restsauerstoffgehalt
|
||||
name: "${name} Restsauerstoffgehalt"
|
||||
id: ${name}_Restsauerstoffgehalt
|
||||
register_type: read
|
||||
address: 3
|
||||
unit_of_measurement: "%"
|
||||
@@ -163,43 +156,39 @@ sensor:
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
# - platform: modbus_controller
|
||||
# modbus_controller_id: ${modbus_controller_id}
|
||||
# device_id: ${device_id}
|
||||
# name: "Rücklauffühler"
|
||||
# id: ${lower_name}_Ruecklauffuehler
|
||||
# register_type: read
|
||||
# address: 9
|
||||
# unit_of_measurement: "°C"
|
||||
# value_type: S_WORD
|
||||
# filters:
|
||||
# - multiply: 0.5
|
||||
|
||||
# - platform: modbus_controller
|
||||
# modbus_controller_id: ${modbus_controller_id}
|
||||
# device_id: ${device_id}
|
||||
# name: "Primärluft"
|
||||
# id: ${lower_name}_Primaerluft
|
||||
# register_type: read
|
||||
# address: 11
|
||||
# unit_of_measurement: "%"
|
||||
# value_type: U_WORD
|
||||
|
||||
# - platform: modbus_controller
|
||||
# modbus_controller_id: ${modbus_controller_id}
|
||||
# device_id: ${device_id}
|
||||
# name: "Sekundärluft"
|
||||
# id: ${lower_name}_Sekundaerluft
|
||||
# register_type: read
|
||||
# address: 12
|
||||
# unit_of_measurement: "%"
|
||||
# value_type: U_WORD
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Rücklauffühler"
|
||||
id: ${name}_Ruecklauffuehler
|
||||
register_type: read
|
||||
address: 9
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Kesselstellgröße"
|
||||
id: ${lower_name}_Kesselstellgroesse
|
||||
name: "${name} Primärluft"
|
||||
id: ${name}_Primaerluft
|
||||
register_type: read
|
||||
address: 11
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Sekundärluft"
|
||||
id: ${name}_Sekundaerluft
|
||||
register_type: read
|
||||
address: 12
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Kesselstellgröße"
|
||||
id: ${name}_Kesselstellgroesse
|
||||
register_type: read
|
||||
address: 14
|
||||
unit_of_measurement: "%"
|
||||
@@ -207,9 +196,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Betriebsstunden"
|
||||
id: ${lower_name}_Betriebsstunden
|
||||
name: "${name} Betriebsstunden"
|
||||
id: ${name}_Betriebsstunden
|
||||
register_type: read
|
||||
address: 20
|
||||
unit_of_measurement: "h"
|
||||
@@ -217,18 +205,16 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Anzahl der Brennerstarts"
|
||||
id: ${lower_name}_Anzahl_der_Brennerstarts
|
||||
name: "${name} Anzahl der Brennerstarts"
|
||||
id: ${name}_Anzahl_der_Brennerstarts
|
||||
register_type: read
|
||||
address: 22
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Betriebsstunden in der Feuererhaltung"
|
||||
id: ${lower_name}_Betriebsstunden_in_der_Feuererhaltung
|
||||
name: "${name} Betriebsstunden in der Feuererhaltung"
|
||||
id: ${name}_Betriebsstunden_in_der_Feuererhaltung
|
||||
register_type: read
|
||||
address: 24
|
||||
unit_of_measurement: "h"
|
||||
@@ -236,9 +222,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Errechnete Kesselsolltemperatur"
|
||||
id: ${lower_name}_Errechnete_Kesselsolltemperatur
|
||||
name: "${name} Errechnete Kesselsolltemperatur"
|
||||
id: ${name}_Errechnete_Kesselsolltemperatur
|
||||
register_type: read
|
||||
address: 27
|
||||
unit_of_measurement: "°C"
|
||||
@@ -248,9 +233,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Stunden seit letzter Wartung"
|
||||
id: ${lower_name}_Stunden_seit_letzter_Wartung
|
||||
name: "${name} Stunden seit letzter Wartung"
|
||||
id: ${name}_Stunden_seit_letzter_Wartung
|
||||
register_type: read
|
||||
address: 55
|
||||
unit_of_measurement: "h"
|
||||
@@ -258,9 +242,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Verbleibende Heizstunden bis zur Asche entleeren Warnung"
|
||||
id: ${lower_name}_Verbleibende_Heizstunden_bis_zur_Asche_entleeren_Warnung
|
||||
name: "${name} Verbleibende Heizstunden bis zur Asche entleeren Warnung"
|
||||
id: ${name}_Verbleibende_Heizstunden_bis_zur_Asche_entleeren_Warnung
|
||||
register_type: read
|
||||
address: 86
|
||||
unit_of_measurement: "h"
|
||||
@@ -268,25 +251,21 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Aussentemperatur"
|
||||
id: ${lower_name}_Aussentemperatur
|
||||
name: "${name} Aussentemperatur"
|
||||
id: ${name}_Aussentemperatur
|
||||
register_type: read
|
||||
address: 1000
|
||||
unit_of_measurement: "°C"
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
value_type: S_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
device_id: ${device_id}
|
||||
name: "Kesselzustand Heizen"
|
||||
id: ${lower_name}_Kesselzustand_Heizen
|
||||
name: "${name} Kesselzustand Heizen"
|
||||
id: ${name}_Kesselzustand_Heizen
|
||||
lambda: |-
|
||||
if (id(${lower_name}_Kesselzustand).state == "Heizen") {
|
||||
if (id(${name}_Kesselzustand).state == "Heizen") {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
@@ -295,11 +274,9 @@ binary_sensor:
|
||||
number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Kessel-Solltemperatur"
|
||||
id: ${lower_name}_Kessel_Solltemperatur
|
||||
name: "${name} Kessel-Solltemperatur"
|
||||
id: ${name}_Kessel_Solltemperatur
|
||||
address: 0
|
||||
entity_category: config
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
|
||||
+7
-10
@@ -1,9 +1,8 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Drehzahl Netzpumpe"
|
||||
id: ${lower_name}_Drehzahl_Netzpumpe
|
||||
name: "${name} Drehzahl Netzpumpe"
|
||||
id: ${name}_Drehzahl_Netzpumpe
|
||||
register_type: read
|
||||
address: 700
|
||||
unit_of_measurement: "%"
|
||||
@@ -11,9 +10,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Netzrücklauf Temperatur"
|
||||
id: ${lower_name}_Netzruecklauf_Temperatur
|
||||
name: "${name} Netzrücklauf Temperatur"
|
||||
id: ${name}_Netzruecklauf_Temperatur
|
||||
register_type: read
|
||||
address: 701
|
||||
unit_of_measurement: "°C"
|
||||
@@ -23,11 +21,10 @@ sensor:
|
||||
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
device_id: ${device_id}
|
||||
name: "Netzpumpe AN AUS"
|
||||
id: ${lower_name}_Netzpumpe_AN_AUS
|
||||
name: "${name} Netzpumpe AN AUS"
|
||||
id: ${name}_Netzpumpe_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${lower_name}_Drehzahl_Netzpumpe).state > 0) {
|
||||
if (id(${name}_Drehzahl_Netzpumpe).state > 0) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
|
||||
+13
-19
@@ -1,9 +1,8 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Temperatur oben"
|
||||
id: ${lower_name}_Puffer_1_Temperatur_oben
|
||||
name: "${puffer1_name} Temperatur oben"
|
||||
id: ${name}_Puffer_1_Temperatur_oben
|
||||
register_type: read
|
||||
address: 2000
|
||||
unit_of_measurement: "°C"
|
||||
@@ -13,9 +12,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Temperatur mitte"
|
||||
id: ${lower_name}_Puffer_1_Temperatur_mitte
|
||||
name: "${puffer1_name} Temperatur mitte"
|
||||
id: ${name}_Puffer_1_Temperatur_mitte
|
||||
register_type: read
|
||||
address: 2001
|
||||
unit_of_measurement: "°C"
|
||||
@@ -25,9 +23,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Temperatur unten"
|
||||
id: ${lower_name}_Puffer_1_Temperatur_unten
|
||||
name: "${puffer1_name} Temperatur unten"
|
||||
id: ${name}_Puffer_1_Temperatur_unten
|
||||
register_type: read
|
||||
address: 2002
|
||||
unit_of_measurement: "°C"
|
||||
@@ -37,9 +34,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Ladezustand"
|
||||
id: ${lower_name}_Puffer_1_Ladezustand
|
||||
name: "${puffer1_name} Ladezustand"
|
||||
id: ${name}_Puffer_1_Ladezustand
|
||||
register_type: read
|
||||
address: 2006
|
||||
unit_of_measurement: "%"
|
||||
@@ -47,9 +43,8 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
device_id: ${device_id}
|
||||
name: "Pufferpumpen Ansteuerung"
|
||||
id: ${lower_name}_Puffer_1_Pufferpumpen_Ansteuerung
|
||||
name: "${puffer1_name} Pufferpumpen Ansteuerung"
|
||||
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung
|
||||
register_type: read
|
||||
address: 2003
|
||||
unit_of_measurement: "%"
|
||||
@@ -57,11 +52,10 @@ sensor:
|
||||
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
device_id: ${device_id}
|
||||
name: "Pufferpumpen Ansteuerung AN AUS"
|
||||
id: ${lower_name}_Puffer_1_Pufferpumpen_Ansteuerung_AN_AUS
|
||||
name: "${puffer1_name} Pufferpumpen Ansteuerung AN AUS"
|
||||
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${lower_name}_Puffer_1_Pufferpumpen_Ansteuerung).state > 0) {
|
||||
if (id(${name}_Puffer_1_Pufferpumpen_Ansteuerung).state > 0) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
|
||||
@@ -2,7 +2,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Ruecklauftemperatur an der Zirkulations Leitung"
|
||||
id: ${lower_name}_Ruecklauftemperatur_an_der_Zirkulations_Leitung
|
||||
id: ${name}_Ruecklauftemperatur_an_der_Zirkulations_Leitung
|
||||
register_type: read
|
||||
address: 711
|
||||
unit_of_measurement: "°C"
|
||||
@@ -13,7 +13,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Strömungsschalter an der Brauchwasser Leitung"
|
||||
id: ${lower_name}_Stoemungsschalter_an_der_Brauchwasser_Leitung
|
||||
id: ${name}_Stoemungsschalter_an_der_Brauchwasser_Leitung
|
||||
register_type: read
|
||||
address: 600
|
||||
value_type: U_WORD
|
||||
@@ -21,7 +21,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Drehzahl der Zirkulations Pumpe"
|
||||
id: ${lower_name}_Drehzahl_der_Zirkulations_Pumpe
|
||||
id: ${name}_Drehzahl_der_Zirkulations_Pumpe
|
||||
register_type: read
|
||||
address: 710
|
||||
unit_of_measurement: "%"
|
||||
@@ -30,9 +30,9 @@ sensor:
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${name} Zirkulationspumpe AN AUS"
|
||||
id: ${lower_name}_Zirkulations_Pumpe_AN_AUS
|
||||
id: ${name}_Zirkulations_Pumpe_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${lower_name}_Drehzahl_der_Zirkulations_Pumpe).state > 0) {
|
||||
if (id(${name}_Drehzahl_der_Zirkulations_Pumpe).state > 0) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
@@ -42,7 +42,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Bei welcher RL Temperatur an der Zirkulationsleitung soll die Pumpe ausschalten"
|
||||
id: ${lower_name}_Bei_welcher_RL_Temperatur_an_der_Zirkulationsleitung_soll_die_Pumpe_ausschalten
|
||||
id: ${name}_Bei_welcher_RL_Temperatur_an_der_Zirkulationsleitung_soll_die_Pumpe_ausschalten
|
||||
address: 600
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
|
||||
Reference in new issue
Block a user