@@ -1,7 +1,7 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Boiler 1 Temperatur oben"
|
||||
name: "${Boiler1_name} Temperatur oben"
|
||||
id: ${name}_Boiler_1_Temperatur_oben
|
||||
register_type: read
|
||||
address: 1630
|
||||
@@ -12,7 +12,7 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Boiler 1 Pumpe Ansteuerung"
|
||||
name: "${Boiler1_name} Pumpe Ansteuerung"
|
||||
id: ${name}_Boiler_1_Pumpe_Ansteuerung
|
||||
register_type: read
|
||||
address: 1632
|
||||
@@ -22,7 +22,7 @@ sensor:
|
||||
number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Boiler 1 Gewünschte Boilertemperatur"
|
||||
name: "${Boiler1_name} Gewünschte Boilertemperatur"
|
||||
id: ${name}_Boiler_1_Gewuenschte_Boilertemperatur
|
||||
address: 1631
|
||||
unit_of_measurement: "°C"
|
||||
@@ -33,7 +33,7 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Boiler 1 Nachladen, wenn Boilertemperatur unter"
|
||||
name: "${Boiler1_name} Nachladen, wenn Boilertemperatur unter"
|
||||
id: ${name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
|
||||
address: 1632
|
||||
unit_of_measurement: "°C"
|
||||
@@ -44,7 +44,7 @@ number:
|
||||
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${name} Boiler 1 Pumpe Ansteuerung AN AUS"
|
||||
name: "${Boiler1_name} Pumpe Ansteuerung AN AUS"
|
||||
id: ${name}_Boiler_1_Pumpe_Ansteuerung_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${name}_Boiler_1_Pumpe_Ansteuerung).state > 0) {
|
||||
|
||||
@@ -1,7 +1,27 @@
|
||||
select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Betriebsart"
|
||||
id: ${name}_HK1_Betriebsart
|
||||
options:
|
||||
- "Aus"
|
||||
- "Automatik"
|
||||
- "Extraheizen"
|
||||
- "Absenken"
|
||||
- "Dauerabsenken"
|
||||
- "Partybetrieb"
|
||||
initial_option: "Aus"
|
||||
address: 8046
|
||||
value_type: U_WORD
|
||||
min_value: 0
|
||||
max_value: 5
|
||||
|
||||
|
||||
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Vorlauf-Isttemperatur"
|
||||
name: "${hk1_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1030 #Wrong ?
|
||||
@@ -12,7 +32,7 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Vorlauf-Solltemperatur"
|
||||
name: "${hk1_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1031 #Wrong ?
|
||||
@@ -23,10 +43,10 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Aussentemperatur"
|
||||
id: ${name}_Aussentemperatur
|
||||
name: "${hk1_name} - Raumtemperatur"
|
||||
id: ${name}_HK1_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1000
|
||||
address: 1032 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
@@ -35,7 +55,7 @@ sensor:
|
||||
binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Pumpe AN AUS"
|
||||
name: "${hk1_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK1_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
#address: 999 # Heizkreispumpe 0
|
||||
@@ -45,7 +65,7 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1032
|
||||
unit_of_measurement: "°C"
|
||||
@@ -57,7 +77,7 @@ number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1031
|
||||
unit_of_measurement: "°C"
|
||||
@@ -68,7 +88,7 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
name: "${hk1_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1039
|
||||
unit_of_measurement: "°C"
|
||||
@@ -79,7 +99,7 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
name: "${hk1_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1033
|
||||
unit_of_measurement: "°C"
|
||||
@@ -90,7 +110,7 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1036
|
||||
unit_of_measurement: "°C"
|
||||
@@ -101,7 +121,7 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1037
|
||||
unit_of_measurement: "°C"
|
||||
@@ -112,7 +132,7 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Frostschutztemperatur"
|
||||
name: "${hk1_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK1_Frostschutztemperatur
|
||||
address: 1038
|
||||
unit_of_measurement: "°C"
|
||||
@@ -123,10 +143,11 @@ number:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${heizkreisname} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
name: "${hk1_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1047
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
min_value: 60
|
||||
max_value: 120
|
||||
|
||||
@@ -0,0 +1,134 @@
|
||||
# Heizkreis 2 ist noch nicht komplett fertig
|
||||
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1060 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1061 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Raumtemperatur"
|
||||
id: ${name}_HK2_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1062 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK2_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
#address: 999 # Heizkreispumpe 0
|
||||
address: 1029 # Heizkreispumpe 1 - wrong ?
|
||||
|
||||
number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1031
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 110
|
||||
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1032
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 110
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1033
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 0
|
||||
max_value: 70
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1039
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 30
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1036
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: -20
|
||||
max_value: 50
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1037
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: -20
|
||||
max_value: 50
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK2_Frostschutztemperatur
|
||||
address: 1038
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: -10
|
||||
max_value: 20
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1047
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
min_value: 60
|
||||
max_value: 120
|
||||
+11
@@ -221,6 +221,17 @@ sensor:
|
||||
unit_of_measurement: "h"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Aussentemperatur"
|
||||
id: ${name}_Aussentemperatur
|
||||
register_type: read
|
||||
address: 1000
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${name} Kesselzustand Heizen"
|
||||
|
||||
+6
-6
@@ -1,7 +1,7 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Puffer 1 Temperatur oben"
|
||||
name: "${Puffer1_name} Temperatur oben"
|
||||
id: ${name}_Puffer_1_Temperatur_oben
|
||||
register_type: read
|
||||
address: 2000
|
||||
@@ -12,7 +12,7 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Puffer 1 Temperatur mitte"
|
||||
name: "${Puffer1_name} Temperatur mitte"
|
||||
id: ${name}_Puffer_1_Temperatur_mitte
|
||||
register_type: read
|
||||
address: 2001
|
||||
@@ -23,7 +23,7 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Puffer 1 Temperatur unten"
|
||||
name: "${Puffer1_name} Temperatur unten"
|
||||
id: ${name}_Puffer_1_Temperatur_unten
|
||||
register_type: read
|
||||
address: 2002
|
||||
@@ -34,7 +34,7 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Puffer 1 Ladezustand"
|
||||
name: "${Puffer1_name} Ladezustand"
|
||||
id: ${name}_Puffer_1_Ladezustand
|
||||
register_type: read
|
||||
address: 2006
|
||||
@@ -43,7 +43,7 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Puffer 1 Pufferpumpen Ansteuerung"
|
||||
name: "${Puffer1_name} Pufferpumpen Ansteuerung"
|
||||
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung
|
||||
register_type: read
|
||||
address: 2003
|
||||
@@ -52,7 +52,7 @@ sensor:
|
||||
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${name} Puffer 1 Pufferpumpen Ansteuerung AN AUS"
|
||||
name: "${Puffer1_name} Pufferpumpen Ansteuerung AN AUS"
|
||||
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${name}_Puffer_1_Pufferpumpen_Ansteuerung).state > 0) {
|
||||
|
||||
Reference in new issue