@@ -205,11 +205,10 @@ sensor:
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Stunden seit letzter Wartung"
|
||||
id: ${name}_Stunden_seit_letzter_Wartung
|
||||
name: "${name} Anzahl der Brennerstarts"
|
||||
id: ${name}_Anzahl_der_Brennerstarts
|
||||
register_type: read
|
||||
address: 55
|
||||
unit_of_measurement: "h"
|
||||
address: 22
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
@@ -221,6 +220,26 @@ sensor:
|
||||
unit_of_measurement: "h"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Errechnete Kesselsolltemperatur"
|
||||
id: ${name}_Errechnete_Kesselsolltemperatur
|
||||
register_type: read
|
||||
address: 27
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Stunden seit letzter Wartung"
|
||||
id: ${name}_Stunden_seit_letzter_Wartung
|
||||
register_type: read
|
||||
address: 55
|
||||
unit_of_measurement: "h"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Verbleibende Heizstunden bis zur Asche entleeren Warnung"
|
||||
@@ -261,5 +280,5 @@ number:
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 70
|
||||
min_value: 40
|
||||
max_value: 90
|
||||
|
||||
@@ -1,51 +1,31 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Ruecklauftemperatur an der Zirkulations Leitung"
|
||||
id: ${name}_Ruecklauftemperatur_an_der_Zirkulations_Leitung
|
||||
name: "${name} Drehzahl Netzpumpe"
|
||||
id: ${name}_Drehzahl_Netzpumpe
|
||||
register_type: read
|
||||
address: 711
|
||||
address: 700
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Netzrücklauf Temperatur"
|
||||
id: ${name}_Netzrücklauf_Temperatur
|
||||
register_type: read
|
||||
address: 701
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Strömungsschalter an der Brauchwasser Leitung"
|
||||
id: ${name}_Stoemungsschalter_an_der_Brauchwasser_Leitung
|
||||
register_type: read
|
||||
address: 600
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Drehzahl der Zirkulations Pumpe"
|
||||
id: ${name}_Drehzahl_der_Zirkulations_Pumpe
|
||||
register_type: read
|
||||
address: 710
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${name} Zirkulationspumpe AN AUS"
|
||||
id: ${name}_Zirkulations_Pumpe_AN_AUS
|
||||
name: "${name} Netzpumpe AN AUS"
|
||||
id: ${name}_Netzpumpe_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${name}_Drehzahl_der_Zirkulations_Pumpe).state > 0) {
|
||||
if (id(${name}_Drehzahl_Netzpumpe).state > 0) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
}
|
||||
|
||||
number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Bei welcher RL Temperatur an der Zirkulationsleitung soll die Pumpe ausschalten"
|
||||
id: ${name}_Bei_welcher_RL_Temperatur_an_der_Zirkulationsleitung_soll_die_Pumpe_ausschalten
|
||||
address: 600
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
multiply: 2
|
||||
min_value: 20
|
||||
max_value: 120
|
||||
|
||||