@@ -0,0 +1,153 @@
|
||||
select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Betriebsart"
|
||||
id: ${name}_HK1_Betriebsart
|
||||
options:
|
||||
- "Aus"
|
||||
- "Automatik"
|
||||
- "Extraheizen"
|
||||
- "Absenken"
|
||||
- "Dauerabsenken"
|
||||
- "Partybetrieb"
|
||||
initial_option: "Aus"
|
||||
address: 8046
|
||||
value_type: U_WORD
|
||||
min_value: 0
|
||||
max_value: 5
|
||||
|
||||
|
||||
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1030 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1031 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Raumtemperatur"
|
||||
id: ${name}_HK1_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1032 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK1_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
#address: 999 # Heizkreispumpe 0
|
||||
address: 1029 # Heizkreispumpe 1 - wrong ?
|
||||
|
||||
number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1032
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 110
|
||||
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1031
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 110
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1039
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 30
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1033
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 0
|
||||
max_value: 70
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1036
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: -20
|
||||
max_value: 50
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1037
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: -20
|
||||
max_value: 50
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK1_Frostschutztemperatur
|
||||
address: 1038
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: -10
|
||||
max_value: 20
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1047
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
min_value: 60
|
||||
max_value: 120
|
||||
|
||||