diff --git a/boiler_01.yaml b/boiler_01.yaml index 90f563e..9f0d891 100644 --- a/boiler_01.yaml +++ b/boiler_01.yaml @@ -1,7 +1,7 @@ sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${name} Boiler 1 Temperatur oben" + name: "${Boiler1_name} Temperatur oben" id: ${name}_Boiler_1_Temperatur_oben register_type: read address: 1630 @@ -12,7 +12,7 @@ sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${name} Boiler 1 Pumpe Ansteuerung" + name: "${Boiler1_name} Pumpe Ansteuerung" id: ${name}_Boiler_1_Pumpe_Ansteuerung register_type: read address: 1632 @@ -22,7 +22,7 @@ sensor: number: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${name} Boiler 1 Gewünschte Boilertemperatur" + name: "${Boiler1_name} Gewünschte Boilertemperatur" id: ${name}_Boiler_1_Gewuenschte_Boilertemperatur address: 1631 unit_of_measurement: "°C" @@ -33,7 +33,7 @@ number: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${name} Boiler 1 Nachladen, wenn Boilertemperatur unter" + name: "${Boiler1_name} Nachladen, wenn Boilertemperatur unter" id: ${name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter address: 1632 unit_of_measurement: "°C" @@ -44,7 +44,7 @@ number: binary_sensor: - platform: template - name: "${name} Boiler 1 Pumpe Ansteuerung AN AUS" + name: "${Boiler1_name} Pumpe Ansteuerung AN AUS" id: ${name}_Boiler_1_Pumpe_Ansteuerung_AN_AUS lambda: |- if (id(${name}_Boiler_1_Pumpe_Ansteuerung).state > 0) { diff --git a/heizkoerper.yaml b/heizkreis_01.yaml similarity index 71% rename from heizkoerper.yaml rename to heizkreis_01.yaml index 7e819e2..733000e 100644 --- a/heizkoerper.yaml +++ b/heizkreis_01.yaml @@ -1,7 +1,27 @@ +select: + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk1_name} - Betriebsart" + id: ${name}_HK1_Betriebsart + options: + - "Aus" + - "Automatik" + - "Extraheizen" + - "Absenken" + - "Dauerabsenken" + - "Partybetrieb" + initial_option: "Aus" + address: 8046 + value_type: U_WORD + min_value: 0 + max_value: 5 + + + sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Vorlauf-Isttemperatur" + name: "${hk1_name} - Vorlauf-Isttemperatur" id: ${name}_HK1_Vorlauf_Isttemperatur register_type: read address: 1030 #Wrong ? @@ -12,7 +32,7 @@ sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Vorlauf-Solltemperatur" + name: "${hk1_name} - Vorlauf-Solltemperatur" id: ${name}_HK1_Vorlauf_Solltemperatur register_type: read address: 1031 #Wrong ? @@ -23,10 +43,10 @@ sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Aussentemperatur" - id: ${name}_Aussentemperatur + name: "${hk1_name} - Raumtemperatur" + id: ${name}_HK1_Raumtemperatur register_type: read - address: 1000 + address: 1032 #Wrong ? unit_of_measurement: "°C" value_type: U_WORD filters: @@ -35,7 +55,7 @@ sensor: binary_sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Pumpe AN AUS" + name: "${hk1_name} - Pumpe AN AUS" id: ${name}_HK1_Pumpe_AN_AUS register_type: coil #address: 999 # Heizkreispumpe 0 @@ -45,7 +65,7 @@ number: # not correct yet ? - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur" + name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur" id: ${name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur address: 1032 unit_of_measurement: "°C" @@ -57,7 +77,7 @@ number: # not correct yet ? - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur" + name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur" id: ${name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur address: 1031 unit_of_measurement: "°C" @@ -68,7 +88,7 @@ number: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als" + name: "${hk1_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als" id: ${name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als address: 1039 unit_of_measurement: "°C" @@ -79,7 +99,7 @@ number: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Absenkung der Vorlauftemperatur im Absenkbetrieb" + name: "${hk1_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb" id: ${name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb address: 1033 unit_of_measurement: "°C" @@ -90,7 +110,7 @@ number: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet" + name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet" id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet address: 1036 unit_of_measurement: "°C" @@ -101,7 +121,7 @@ number: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet" + name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet" id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet address: 1037 unit_of_measurement: "°C" @@ -112,7 +132,7 @@ number: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Frostschutztemperatur" + name: "${hk1_name} - Frostschutztemperatur" id: ${name}_HK1_Frostschutztemperatur address: 1038 unit_of_measurement: "°C" @@ -123,10 +143,11 @@ number: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${heizkreisname} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird" + name: "${hk1_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird" id: ${name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird address: 1047 unit_of_measurement: "°C" value_type: U_WORD min_value: 60 max_value: 120 + diff --git a/heizkreis_02.yaml b/heizkreis_02.yaml new file mode 100644 index 0000000..a2c7997 --- /dev/null +++ b/heizkreis_02.yaml @@ -0,0 +1,134 @@ +# Heizkreis 2 ist noch nicht komplett fertig + +sensor: + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Vorlauf-Isttemperatur" + id: ${name}_HK2_Vorlauf_Isttemperatur + register_type: read + address: 1060 #Wrong ? + unit_of_measurement: "°C" + value_type: U_WORD + filters: + - multiply: 0.5 + + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Vorlauf-Solltemperatur" + id: ${name}_HK2_Vorlauf_Solltemperatur + register_type: read + address: 1061 #Wrong ? + unit_of_measurement: "°C" + value_type: U_WORD + filters: + - multiply: 0.5 + + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Raumtemperatur" + id: ${name}_HK2_Raumtemperatur + register_type: read + address: 1062 #Wrong ? + unit_of_measurement: "°C" + value_type: U_WORD + filters: + - multiply: 0.5 + +binary_sensor: + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Pumpe AN AUS" + id: ${name}_HK2_Pumpe_AN_AUS + register_type: coil + #address: 999 # Heizkreispumpe 0 + address: 1029 # Heizkreispumpe 1 - wrong ? + +number: + # not correct yet ? + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur" + id: ${name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur + address: 1031 + unit_of_measurement: "°C" + value_type: U_WORD + multiply: 2 + min_value: 10 + max_value: 110 + + # not correct yet ? + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur" + id: ${name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur + address: 1032 + unit_of_measurement: "°C" + value_type: U_WORD + multiply: 2 + min_value: 10 + max_value: 110 + + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb" + id: ${name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb + address: 1033 + unit_of_measurement: "°C" + value_type: U_WORD + multiply: 2 + min_value: 0 + max_value: 70 + + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als" + id: ${name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als + address: 1039 + unit_of_measurement: "°C" + value_type: U_WORD + multiply: 2 + min_value: 10 + max_value: 30 + + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet" + id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet + address: 1036 + unit_of_measurement: "°C" + value_type: U_WORD + multiply: 2 + min_value: -20 + max_value: 50 + + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet" + id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet + address: 1037 + unit_of_measurement: "°C" + value_type: U_WORD + multiply: 2 + min_value: -20 + max_value: 50 + + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Frostschutztemperatur" + id: ${name}_HK2_Frostschutztemperatur + address: 1038 + unit_of_measurement: "°C" + value_type: U_WORD + multiply: 2 + min_value: -10 + max_value: 20 + + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${hk2_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird" + id: ${name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird + address: 1047 + unit_of_measurement: "°C" + value_type: U_WORD + min_value: 60 + max_value: 120 diff --git a/kessel.yaml b/kessel.yaml index 9c5bafb..b5d5921 100644 --- a/kessel.yaml +++ b/kessel.yaml @@ -221,6 +221,17 @@ sensor: unit_of_measurement: "h" value_type: U_WORD + - platform: modbus_controller + modbus_controller_id: ${modbus_controller_id} + name: "${name} Aussentemperatur" + id: ${name}_Aussentemperatur + register_type: read + address: 1000 + unit_of_measurement: "°C" + value_type: U_WORD + filters: + - multiply: 0.5 + binary_sensor: - platform: template name: "${name} Kesselzustand Heizen" diff --git a/puffer_01.yaml b/puffer_01.yaml index f6e1e69..61e3243 100644 --- a/puffer_01.yaml +++ b/puffer_01.yaml @@ -1,7 +1,7 @@ sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${name} Puffer 1 Temperatur oben" + name: "${Puffer1_name} Temperatur oben" id: ${name}_Puffer_1_Temperatur_oben register_type: read address: 2000 @@ -12,7 +12,7 @@ sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${name} Puffer 1 Temperatur mitte" + name: "${Puffer1_name} Temperatur mitte" id: ${name}_Puffer_1_Temperatur_mitte register_type: read address: 2001 @@ -23,7 +23,7 @@ sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${name} Puffer 1 Temperatur unten" + name: "${Puffer1_name} Temperatur unten" id: ${name}_Puffer_1_Temperatur_unten register_type: read address: 2002 @@ -34,7 +34,7 @@ sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${name} Puffer 1 Ladezustand" + name: "${Puffer1_name} Ladezustand" id: ${name}_Puffer_1_Ladezustand register_type: read address: 2006 @@ -43,7 +43,7 @@ sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} - name: "${name} Puffer 1 Pufferpumpen Ansteuerung" + name: "${Puffer1_name} Pufferpumpen Ansteuerung" id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung register_type: read address: 2003 @@ -52,7 +52,7 @@ sensor: binary_sensor: - platform: template - name: "${name} Puffer 1 Pufferpumpen Ansteuerung AN AUS" + name: "${Puffer1_name} Pufferpumpen Ansteuerung AN AUS" id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung_AN_AUS lambda: |- if (id(${name}_Puffer_1_Pufferpumpen_Ansteuerung).state > 0) {