sensor:
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${boiler1_name} Temperatur oben"
|
|
id: ${lower_name}_Boiler_1_Temperatur_oben
|
|
register_type: read
|
|
address: 1630
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
filters:
|
|
- multiply: 0.5
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${boiler1_name} Pumpe Ansteuerung"
|
|
id: ${lower_name}_Boiler_1_Pumpe_Ansteuerung
|
|
register_type: read
|
|
address: 1632
|
|
unit_of_measurement: "%"
|
|
value_type: U_WORD
|
|
|
|
number:
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${boiler1_name} Gewünschte Boilertemperatur"
|
|
id: ${lower_name}_Boiler_1_Gewuenschte_Boilertemperatur
|
|
address: 1631
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
multiply: 2
|
|
min_value: 10
|
|
max_value: 100
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${boiler1_name} Nachladen, wenn Boilertemperatur unter"
|
|
id: ${lower_name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
|
|
address: 1632
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
multiply: 2
|
|
min_value: 1
|
|
max_value: 90
|
|
|
|
binary_sensor:
|
|
- platform: template
|
|
name: "${boiler1_name} Pumpe Ansteuerung AN AUS"
|
|
id: ${lower_name}_Boiler_1_Pumpe_Ansteuerung_AN_AUS
|
|
lambda: |-
|
|
if (id(${lower_name}_Boiler_1_Pumpe_Ansteuerung).state > 0) {
|
|
return true;
|
|
} else {
|
|
return false;
|
|
} |