update
Test Name asd asd rename asd asd sdfg typo typo c header asdf error fehler update example asd sdf xcv adsf adress dfas Singed Values Temperature asd ü asd Change id entferne unbenutzte werte entity_category, state_class usw entity_category, state_class usw
This commit is contained in:
@@ -36,6 +36,8 @@ sensor:
|
|||||||
register_type: read
|
register_type: read
|
||||||
address: 83
|
address: 83
|
||||||
unit_of_measurement: "t"
|
unit_of_measurement: "t"
|
||||||
|
state_class: total_increasing
|
||||||
|
device_class: weight
|
||||||
accuracy_decimals: 1
|
accuracy_decimals: 1
|
||||||
value_type: U_WORD
|
value_type: U_WORD
|
||||||
filters:
|
filters:
|
||||||
|
|||||||
@@ -6,6 +6,8 @@ sensor:
|
|||||||
register_type: read
|
register_type: read
|
||||||
address: 1630
|
address: 1630
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
|
device_class: temperature
|
||||||
|
state_class: measurement
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
filters:
|
filters:
|
||||||
- multiply: 0.5
|
- multiply: 0.5
|
||||||
@@ -25,6 +27,7 @@ number:
|
|||||||
name: "${boiler1_name} Gewünschte Boilertemperatur"
|
name: "${boiler1_name} Gewünschte Boilertemperatur"
|
||||||
id: ${lower_name}_Boiler_1_Gewuenschte_Boilertemperatur
|
id: ${lower_name}_Boiler_1_Gewuenschte_Boilertemperatur
|
||||||
address: 1631
|
address: 1631
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -36,6 +39,7 @@ number:
|
|||||||
name: "${boiler1_name} Nachladen, wenn Boilertemperatur unter"
|
name: "${boiler1_name} Nachladen, wenn Boilertemperatur unter"
|
||||||
id: ${lower_name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
|
id: ${lower_name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
|
||||||
address: 1632
|
address: 1632
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
|
|||||||
@@ -21,6 +21,8 @@ sensor:
|
|||||||
register_type: read
|
register_type: read
|
||||||
address: 1030 #Wrong ?
|
address: 1030 #Wrong ?
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
|
device_class: temperature
|
||||||
|
state_class: measurement
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
filters:
|
filters:
|
||||||
- multiply: 0.5
|
- multiply: 0.5
|
||||||
@@ -62,6 +64,7 @@ number:
|
|||||||
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||||
id: ${lower_name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
id: ${lower_name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||||
address: 1032
|
address: 1032
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -74,6 +77,7 @@ number:
|
|||||||
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||||
id: ${lower_name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
|
id: ${lower_name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||||
address: 1031
|
address: 1031
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -85,6 +89,7 @@ number:
|
|||||||
name: "${hk1_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
name: "${hk1_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||||
id: ${lower_name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
id: ${lower_name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||||
address: 1039
|
address: 1039
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -96,6 +101,7 @@ number:
|
|||||||
name: "${hk1_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
name: "${hk1_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||||
id: ${lower_name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
id: ${lower_name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||||
address: 1033
|
address: 1033
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -107,6 +113,7 @@ number:
|
|||||||
name: "${hk1_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
name: "${hk1_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||||
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||||
address: 1035
|
address: 1035
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -118,6 +125,7 @@ number:
|
|||||||
name: "${hk1_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
name: "${hk1_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||||
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||||
address: 1040
|
address: 1040
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -129,6 +137,7 @@ number:
|
|||||||
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||||
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||||
address: 1036
|
address: 1036
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -140,6 +149,7 @@ number:
|
|||||||
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||||
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||||
address: 1037
|
address: 1037
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -151,6 +161,7 @@ number:
|
|||||||
name: "${hk1_name} - Frostschutztemperatur"
|
name: "${hk1_name} - Frostschutztemperatur"
|
||||||
id: ${lower_name}_HK1_Frostschutztemperatur
|
id: ${lower_name}_HK1_Frostschutztemperatur
|
||||||
address: 1038
|
address: 1038
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -162,6 +173,7 @@ number:
|
|||||||
name: "${hk1_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
name: "${hk1_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||||
id: ${lower_name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
id: ${lower_name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||||
address: 1047
|
address: 1047
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
min_value: 60
|
min_value: 60
|
||||||
|
|||||||
@@ -21,6 +21,8 @@ sensor:
|
|||||||
register_type: read
|
register_type: read
|
||||||
address: 1060 #Wrong ?
|
address: 1060 #Wrong ?
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
|
device_class: temperature
|
||||||
|
state_class: measurement
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
filters:
|
filters:
|
||||||
- multiply: 0.5
|
- multiply: 0.5
|
||||||
@@ -62,6 +64,7 @@ number:
|
|||||||
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||||
id: ${lower_name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur
|
id: ${lower_name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||||
address: 1061
|
address: 1061
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -74,6 +77,7 @@ number:
|
|||||||
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||||
id: ${lower_name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
id: ${lower_name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||||
address: 1062
|
address: 1062
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -85,6 +89,7 @@ number:
|
|||||||
name: "${hk2_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
name: "${hk2_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||||
id: ${lower_name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
id: ${lower_name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||||
address: 1063
|
address: 1063
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -96,6 +101,7 @@ number:
|
|||||||
name: "${hk2_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
name: "${hk2_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||||
id: ${lower_name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
id: ${lower_name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||||
address: 1069
|
address: 1069
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -107,6 +113,7 @@ number:
|
|||||||
name: "${hk2_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
name: "${hk2_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||||
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||||
address: 1065
|
address: 1065
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -118,6 +125,7 @@ number:
|
|||||||
name: "${hk2_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
name: "${hk2_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||||
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||||
address: 1070
|
address: 1070
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -129,6 +137,7 @@ number:
|
|||||||
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||||
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||||
address: 1066
|
address: 1066
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -140,6 +149,7 @@ number:
|
|||||||
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||||
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||||
address: 1067
|
address: 1067
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -151,6 +161,7 @@ number:
|
|||||||
name: "${hk2_name} - Frostschutztemperatur"
|
name: "${hk2_name} - Frostschutztemperatur"
|
||||||
id: ${lower_name}_HK2_Frostschutztemperatur
|
id: ${lower_name}_HK2_Frostschutztemperatur
|
||||||
address: 1068
|
address: 1068
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -162,6 +173,7 @@ number:
|
|||||||
name: "${hk2_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
name: "${hk2_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||||
id: ${lower_name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
id: ${lower_name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||||
address: 1078
|
address: 1078
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
min_value: 60
|
min_value: 60
|
||||||
|
|||||||
@@ -21,6 +21,8 @@ sensor:
|
|||||||
register_type: read
|
register_type: read
|
||||||
address: 1090 #Wrong ?
|
address: 1090 #Wrong ?
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
|
device_class: temperature
|
||||||
|
state_class: measurement
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
filters:
|
filters:
|
||||||
- multiply: 0.5
|
- multiply: 0.5
|
||||||
@@ -62,6 +64,7 @@ number:
|
|||||||
name: "${hk3_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
name: "${hk3_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||||
id: ${lower_name}_HK3_Vorlauf_Temperatur_10C_Aussentemperatur
|
id: ${lower_name}_HK3_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||||
address: 1091
|
address: 1091
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -74,6 +77,7 @@ number:
|
|||||||
name: "${hk3_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
name: "${hk3_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||||
id: ${lower_name}_HK3_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
id: ${lower_name}_HK3_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||||
address: 1092
|
address: 1092
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -85,6 +89,7 @@ number:
|
|||||||
name: "${hk3_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
name: "${hk3_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||||
id: ${lower_name}_HK3_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
id: ${lower_name}_HK3_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||||
address: 1093
|
address: 1093
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -96,6 +101,7 @@ number:
|
|||||||
name: "${hk3_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
name: "${hk3_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||||
id: ${lower_name}_HK3_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
id: ${lower_name}_HK3_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||||
address: 1099
|
address: 1099
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -107,6 +113,7 @@ number:
|
|||||||
name: "${hk3_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
name: "${hk3_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||||
id: ${lower_name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
id: ${lower_name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||||
address: 1095
|
address: 1095
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -118,6 +125,7 @@ number:
|
|||||||
name: "${hk3_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
name: "${hk3_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||||
id: ${lower_name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
id: ${lower_name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||||
address: 1100
|
address: 1100
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -129,6 +137,7 @@ number:
|
|||||||
name: "${hk3_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
name: "${hk3_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||||
id: ${lower_name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
id: ${lower_name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||||
address: 1096
|
address: 1096
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -140,6 +149,7 @@ number:
|
|||||||
name: "${hk3_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
name: "${hk3_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||||
id: ${lower_name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
id: ${lower_name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||||
address: 1097
|
address: 1097
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -151,6 +161,7 @@ number:
|
|||||||
name: "${hk3_name} - Frostschutztemperatur"
|
name: "${hk3_name} - Frostschutztemperatur"
|
||||||
id: ${lower_name}_HK3_Frostschutztemperatur
|
id: ${lower_name}_HK3_Frostschutztemperatur
|
||||||
address: 1098
|
address: 1098
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -162,6 +173,7 @@ number:
|
|||||||
name: "${hk3_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
name: "${hk3_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||||
id: ${lower_name}_HK3_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
id: ${lower_name}_HK3_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||||
address: 1105
|
address: 1105
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
min_value: 60
|
min_value: 60
|
||||||
|
|||||||
@@ -21,6 +21,8 @@ sensor:
|
|||||||
register_type: read
|
register_type: read
|
||||||
address: 1120 #Wrong ?
|
address: 1120 #Wrong ?
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
|
device_class: temperature
|
||||||
|
state_class: measurement
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
filters:
|
filters:
|
||||||
- multiply: 0.5
|
- multiply: 0.5
|
||||||
@@ -62,6 +64,7 @@ number:
|
|||||||
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||||
id: ${lower_name}_HK4_Vorlauf_Temperatur_10C_Aussentemperatur
|
id: ${lower_name}_HK4_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||||
address: 1121
|
address: 1121
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -74,6 +77,7 @@ number:
|
|||||||
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||||
id: ${lower_name}_HK4_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
id: ${lower_name}_HK4_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||||
address: 1122
|
address: 1122
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -85,6 +89,7 @@ number:
|
|||||||
name: "${hk4_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
name: "${hk4_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||||
id: ${lower_name}_HK4_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
id: ${lower_name}_HK4_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||||
address: 1123
|
address: 1123
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -96,6 +101,7 @@ number:
|
|||||||
name: "${hk4_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
name: "${hk4_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||||
id: ${lower_name}_HK4_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
id: ${lower_name}_HK4_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||||
address: 1129
|
address: 1129
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -107,6 +113,7 @@ number:
|
|||||||
name: "${hk4_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
name: "${hk4_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||||
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||||
address: 1125
|
address: 1125
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -118,6 +125,7 @@ number:
|
|||||||
name: "${hk4_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
name: "${hk4_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||||
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||||
address: 1130
|
address: 1130
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -129,6 +137,7 @@ number:
|
|||||||
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||||
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||||
address: 1126
|
address: 1126
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -140,6 +149,7 @@ number:
|
|||||||
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||||
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||||
address: 1127
|
address: 1127
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -151,6 +161,7 @@ number:
|
|||||||
name: "${hk4_name} - Frostschutztemperatur"
|
name: "${hk4_name} - Frostschutztemperatur"
|
||||||
id: ${lower_name}_HK4_Frostschutztemperatur
|
id: ${lower_name}_HK4_Frostschutztemperatur
|
||||||
address: 1128
|
address: 1128
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -162,6 +173,7 @@ number:
|
|||||||
name: "${hk4_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
name: "${hk4_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||||
id: ${lower_name}_HK4_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
id: ${lower_name}_HK4_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||||
address: 1135
|
address: 1135
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
min_value: 60
|
min_value: 60
|
||||||
|
|||||||
@@ -21,6 +21,8 @@ sensor:
|
|||||||
register_type: read
|
register_type: read
|
||||||
address: 1150 #Wrong ?
|
address: 1150 #Wrong ?
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
|
device_class: temperature
|
||||||
|
state_class: measurement
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
filters:
|
filters:
|
||||||
- multiply: 0.5
|
- multiply: 0.5
|
||||||
@@ -62,6 +64,7 @@ number:
|
|||||||
name: "${hk5_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
name: "${hk5_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||||
id: ${lower_name}_HK5_Vorlauf_Temperatur_10C_Aussentemperatur
|
id: ${lower_name}_HK5_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||||
address: 1151
|
address: 1151
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -74,6 +77,7 @@ number:
|
|||||||
name: "${hk5_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
name: "${hk5_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||||
id: ${lower_name}_HK5_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
id: ${lower_name}_HK5_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||||
address: 1152
|
address: 1152
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -85,6 +89,7 @@ number:
|
|||||||
name: "${hk5_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
name: "${hk5_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||||
id: ${lower_name}_HK5_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
id: ${lower_name}_HK5_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||||
address: 1153
|
address: 1153
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -96,6 +101,7 @@ number:
|
|||||||
name: "${hk5_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
name: "${hk5_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||||
id: ${lower_name}_HK5_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
id: ${lower_name}_HK5_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||||
address: 1159
|
address: 1159
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -107,6 +113,7 @@ number:
|
|||||||
name: "${hk5_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
name: "${hk5_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||||
id: ${lower_name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
id: ${lower_name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||||
address: 1155
|
address: 1155
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -118,6 +125,7 @@ number:
|
|||||||
name: "${hk5_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
name: "${hk5_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||||
id: ${lower_name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
id: ${lower_name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||||
address: 1160
|
address: 1160
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -129,6 +137,7 @@ number:
|
|||||||
name: "${hk5_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
name: "${hk5_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||||
id: ${lower_name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
id: ${lower_name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||||
address: 1156
|
address: 1156
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -140,6 +149,7 @@ number:
|
|||||||
name: "${hk5_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
name: "${hk5_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||||
id: ${lower_name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
id: ${lower_name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||||
address: 1157
|
address: 1157
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -151,6 +161,7 @@ number:
|
|||||||
name: "${hk5_name} - Frostschutztemperatur"
|
name: "${hk5_name} - Frostschutztemperatur"
|
||||||
id: ${lower_name}_HK5_Frostschutztemperatur
|
id: ${lower_name}_HK5_Frostschutztemperatur
|
||||||
address: 1158
|
address: 1158
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
@@ -162,6 +173,7 @@ number:
|
|||||||
name: "${hk5_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
name: "${hk5_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||||
id: ${lower_name}_HK5_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
id: ${lower_name}_HK5_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||||
address: 1165
|
address: 1165
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
min_value: 60
|
min_value: 60
|
||||||
|
|||||||
@@ -256,6 +256,8 @@ sensor:
|
|||||||
register_type: read
|
register_type: read
|
||||||
address: 1000
|
address: 1000
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
|
device_class: temperature
|
||||||
|
state_class: measurement
|
||||||
value_type: S_WORD
|
value_type: S_WORD
|
||||||
filters:
|
filters:
|
||||||
- multiply: 0.5
|
- multiply: 0.5
|
||||||
@@ -277,6 +279,7 @@ number:
|
|||||||
name: "${name} Kessel-Solltemperatur"
|
name: "${name} Kessel-Solltemperatur"
|
||||||
id: ${lower_name}_Kessel_Solltemperatur
|
id: ${lower_name}_Kessel_Solltemperatur
|
||||||
address: 0
|
address: 0
|
||||||
|
entity_category: config
|
||||||
unit_of_measurement: "°C"
|
unit_of_measurement: "°C"
|
||||||
value_type: U_WORD
|
value_type: U_WORD
|
||||||
multiply: 2
|
multiply: 2
|
||||||
|
|||||||