sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${boiler1_name} Temperatur oben"
id: ${lower_name}_Boiler_1_Temperatur_oben
register_type: read
address: 1630
unit_of_measurement: "°C"
device_class: temperature
state_class: measurement
value_type: S_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${boiler1_name} Pumpe Ansteuerung"
id: ${lower_name}_Boiler_1_Pumpe_Ansteuerung
register_type: read
address: 1632
unit_of_measurement: "%"
value_type: U_WORD
number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${boiler1_name} Gewünschte Boilertemperatur"
id: ${lower_name}_Boiler_1_Gewuenschte_Boilertemperatur
address: 1631
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 10
max_value: 100
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${boiler1_name} Nachladen, wenn Boilertemperatur unter"
id: ${lower_name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
address: 1632
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 1
max_value: 90
binary_sensor:
- platform: template
name: "${boiler1_name} Pumpe Ansteuerung AN AUS"
id: ${lower_name}_Boiler_1_Pumpe_Ansteuerung_AN_AUS
lambda: |-
if (id(${lower_name}_Boiler_1_Pumpe_Ansteuerung).state > 0) {
return true;
} else {
return false;
}