@@ -6,7 +6,7 @@ sensor:
register_type: read register_type: read
address: 1630 address: 1630
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -26,7 +26,7 @@ number:
id: ${name}_Boiler_1_Gewuenschte_Boilertemperatur id: ${name}_Boiler_1_Gewuenschte_Boilertemperatur
address: 1631 address: 1631
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 100 max_value: 100
@@ -37,7 +37,7 @@ number:
id: ${name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter id: ${name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
address: 1632 address: 1632
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 1 min_value: 1
max_value: 90 max_value: 90
+13 -13
View File
@@ -21,7 +21,7 @@ sensor:
register_type: read register_type: read
address: 1030 #Wrong ? address: 1030 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -32,7 +32,7 @@ sensor:
register_type: read register_type: read
address: 1031 #Wrong ? address: 1031 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -43,7 +43,7 @@ sensor:
register_type: read register_type: read
address: 1032 #Wrong ? address: 1032 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -63,7 +63,7 @@ number:
id: ${name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur id: ${name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1032 address: 1032
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 110 max_value: 110
@@ -75,7 +75,7 @@ number:
id: ${name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur id: ${name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1031 address: 1031
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 110 max_value: 110
@@ -86,7 +86,7 @@ number:
id: ${name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als id: ${name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1039 address: 1039
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -97,7 +97,7 @@ number:
id: ${name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb id: ${name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1033 address: 1033
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 0 min_value: 0
max_value: 70 max_value: 70
@@ -108,7 +108,7 @@ number:
id: ${name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs id: ${name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1035 address: 1035
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -119,7 +119,7 @@ number:
id: ${name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes id: ${name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1040 address: 1040
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -130,7 +130,7 @@ number:
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1036 address: 1036
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -20 min_value: -20
max_value: 50 max_value: 50
@@ -141,7 +141,7 @@ number:
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1037 address: 1037
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -20 min_value: -20
max_value: 50 max_value: 50
@@ -152,7 +152,7 @@ number:
id: ${name}_HK1_Frostschutztemperatur id: ${name}_HK1_Frostschutztemperatur
address: 1038 address: 1038
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -10 min_value: -10
max_value: 20 max_value: 20
@@ -163,6 +163,6 @@ number:
id: ${name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird id: ${name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1047 address: 1047
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
min_value: 60 min_value: 60
max_value: 120 max_value: 120
+13 -13
View File
@@ -21,7 +21,7 @@ sensor:
register_type: read register_type: read
address: 1060 #Wrong ? address: 1060 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -32,7 +32,7 @@ sensor:
register_type: read register_type: read
address: 1061 #Wrong ? address: 1061 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -43,7 +43,7 @@ sensor:
register_type: read register_type: read
address: 1062 #Wrong ? address: 1062 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -63,7 +63,7 @@ number:
id: ${name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur id: ${name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1061 address: 1061
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 110 max_value: 110
@@ -75,7 +75,7 @@ number:
id: ${name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur id: ${name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1062 address: 1062
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 110 max_value: 110
@@ -86,7 +86,7 @@ number:
id: ${name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb id: ${name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1063 address: 1063
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 0 min_value: 0
max_value: 70 max_value: 70
@@ -97,7 +97,7 @@ number:
id: ${name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als id: ${name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1069 address: 1069
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -108,7 +108,7 @@ number:
id: ${name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs id: ${name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1065 address: 1065
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -119,7 +119,7 @@ number:
id: ${name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes id: ${name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1070 address: 1070
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -130,7 +130,7 @@ number:
id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1066 address: 1066
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -20 min_value: -20
max_value: 50 max_value: 50
@@ -141,7 +141,7 @@ number:
id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1067 address: 1067
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -20 min_value: -20
max_value: 50 max_value: 50
@@ -152,7 +152,7 @@ number:
id: ${name}_HK2_Frostschutztemperatur id: ${name}_HK2_Frostschutztemperatur
address: 1068 address: 1068
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -10 min_value: -10
max_value: 20 max_value: 20
@@ -163,6 +163,6 @@ number:
id: ${name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird id: ${name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1078 address: 1078
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
min_value: 60 min_value: 60
max_value: 120 max_value: 120
+13 -13
View File
@@ -21,7 +21,7 @@ sensor:
register_type: read register_type: read
address: 1090 #Wrong ? address: 1090 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -32,7 +32,7 @@ sensor:
register_type: read register_type: read
address: 1091 #Wrong ? address: 1091 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -43,7 +43,7 @@ sensor:
register_type: read register_type: read
address: 1092 #Wrong ? address: 1092 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -63,7 +63,7 @@ number:
id: ${name}_HK3_Vorlauf_Temperatur_10C_Aussentemperatur id: ${name}_HK3_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1091 address: 1091
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 110 max_value: 110
@@ -75,7 +75,7 @@ number:
id: ${name}_HK3_Vorlauf_Temperatur_minus_10C_Aussentemperatur id: ${name}_HK3_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1092 address: 1092
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 110 max_value: 110
@@ -86,7 +86,7 @@ number:
id: ${name}_HK3_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb id: ${name}_HK3_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1093 address: 1093
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 0 min_value: 0
max_value: 70 max_value: 70
@@ -97,7 +97,7 @@ number:
id: ${name}_HK3_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als id: ${name}_HK3_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1099 address: 1099
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -108,7 +108,7 @@ number:
id: ${name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs id: ${name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1095 address: 1095
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -119,7 +119,7 @@ number:
id: ${name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes id: ${name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1100 address: 1100
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -130,7 +130,7 @@ number:
id: ${name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet id: ${name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1096 address: 1096
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -20 min_value: -20
max_value: 50 max_value: 50
@@ -141,7 +141,7 @@ number:
id: ${name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet id: ${name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1097 address: 1097
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -20 min_value: -20
max_value: 50 max_value: 50
@@ -152,7 +152,7 @@ number:
id: ${name}_HK3_Frostschutztemperatur id: ${name}_HK3_Frostschutztemperatur
address: 1098 address: 1098
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -10 min_value: -10
max_value: 20 max_value: 20
@@ -163,6 +163,6 @@ number:
id: ${name}_HK3_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird id: ${name}_HK3_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1105 address: 1105
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
min_value: 60 min_value: 60
max_value: 120 max_value: 120
+13 -13
View File
@@ -21,7 +21,7 @@ sensor:
register_type: read register_type: read
address: 1120 #Wrong ? address: 1120 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -32,7 +32,7 @@ sensor:
register_type: read register_type: read
address: 1121 #Wrong ? address: 1121 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -43,7 +43,7 @@ sensor:
register_type: read register_type: read
address: 1122 #Wrong ? address: 1122 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -63,7 +63,7 @@ number:
id: ${name}_HK4_Vorlauf_Temperatur_10C_Aussentemperatur id: ${name}_HK4_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1121 address: 1121
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 110 max_value: 110
@@ -75,7 +75,7 @@ number:
id: ${name}_HK4_Vorlauf_Temperatur_minus_10C_Aussentemperatur id: ${name}_HK4_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1122 address: 1122
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 110 max_value: 110
@@ -86,7 +86,7 @@ number:
id: ${name}_HK4_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb id: ${name}_HK4_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1123 address: 1123
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 0 min_value: 0
max_value: 70 max_value: 70
@@ -97,7 +97,7 @@ number:
id: ${name}_HK4_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als id: ${name}_HK4_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1129 address: 1129
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -108,7 +108,7 @@ number:
id: ${name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs id: ${name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1125 address: 1125
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -119,7 +119,7 @@ number:
id: ${name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes id: ${name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1130 address: 1130
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -130,7 +130,7 @@ number:
id: ${name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet id: ${name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1126 address: 1126
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -20 min_value: -20
max_value: 50 max_value: 50
@@ -141,7 +141,7 @@ number:
id: ${name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet id: ${name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1127 address: 1127
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -20 min_value: -20
max_value: 50 max_value: 50
@@ -152,7 +152,7 @@ number:
id: ${name}_HK4_Frostschutztemperatur id: ${name}_HK4_Frostschutztemperatur
address: 1128 address: 1128
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -10 min_value: -10
max_value: 20 max_value: 20
@@ -163,6 +163,6 @@ number:
id: ${name}_HK4_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird id: ${name}_HK4_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1135 address: 1135
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
min_value: 60 min_value: 60
max_value: 120 max_value: 120
+13 -13
View File
@@ -21,7 +21,7 @@ sensor:
register_type: read register_type: read
address: 1150 #Wrong ? address: 1150 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -32,7 +32,7 @@ sensor:
register_type: read register_type: read
address: 1151 #Wrong ? address: 1151 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -43,7 +43,7 @@ sensor:
register_type: read register_type: read
address: 1152 #Wrong ? address: 1152 #Wrong ?
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -63,7 +63,7 @@ number:
id: ${name}_HK5_Vorlauf_Temperatur_10C_Aussentemperatur id: ${name}_HK5_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1151 address: 1151
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 110 max_value: 110
@@ -75,7 +75,7 @@ number:
id: ${name}_HK5_Vorlauf_Temperatur_minus_10C_Aussentemperatur id: ${name}_HK5_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1152 address: 1152
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 110 max_value: 110
@@ -86,7 +86,7 @@ number:
id: ${name}_HK5_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb id: ${name}_HK5_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1153 address: 1153
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 0 min_value: 0
max_value: 70 max_value: 70
@@ -97,7 +97,7 @@ number:
id: ${name}_HK5_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als id: ${name}_HK5_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1159 address: 1159
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -108,7 +108,7 @@ number:
id: ${name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs id: ${name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1155 address: 1155
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -119,7 +119,7 @@ number:
id: ${name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes id: ${name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1160 address: 1160
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 10 min_value: 10
max_value: 30 max_value: 30
@@ -130,7 +130,7 @@ number:
id: ${name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet id: ${name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1156 address: 1156
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -20 min_value: -20
max_value: 50 max_value: 50
@@ -141,7 +141,7 @@ number:
id: ${name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet id: ${name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1157 address: 1157
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -20 min_value: -20
max_value: 50 max_value: 50
@@ -152,7 +152,7 @@ number:
id: ${name}_HK5_Frostschutztemperatur id: ${name}_HK5_Frostschutztemperatur
address: 1158 address: 1158
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: -10 min_value: -10
max_value: 20 max_value: 20
@@ -163,6 +163,6 @@ number:
id: ${name}_HK5_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird id: ${name}_HK5_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1165 address: 1165
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
min_value: 60 min_value: 60
max_value: 120 max_value: 120
+3 -3
View File
@@ -104,7 +104,7 @@ sensor:
register_type: read register_type: read
address: 0 address: 0
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -115,7 +115,7 @@ sensor:
register_type: read register_type: read
address: 1 address: 1
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
- platform: modbus_controller - platform: modbus_controller
modbus_controller_id: ${modbus_controller_id} modbus_controller_id: ${modbus_controller_id}
@@ -163,7 +163,7 @@ sensor:
register_type: read register_type: read
address: 9 address: 9
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
+2 -2
View File
@@ -6,7 +6,7 @@ sensor:
register_type: read register_type: read
address: 711 address: 711
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -45,7 +45,7 @@ number:
id: ${name}_Bei_welcher_RL_Temperatur_an_der_Zirkulationsleitung_soll_die_Pumpe_ausschalten id: ${name}_Bei_welcher_RL_Temperatur_an_der_Zirkulationsleitung_soll_die_Pumpe_ausschalten
address: 600 address: 600
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
multiply: 2 multiply: 2
min_value: 20 min_value: 20
max_value: 120 max_value: 120
+3 -3
View File
@@ -6,7 +6,7 @@ sensor:
register_type: read register_type: read
address: 2000 address: 2000
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -17,7 +17,7 @@ sensor:
register_type: read register_type: read
address: 2001 address: 2001
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5
@@ -28,7 +28,7 @@ sensor:
register_type: read register_type: read
address: 2002 address: 2002
unit_of_measurement: "°C" unit_of_measurement: "°C"
value_type: U_WORD value_type: S_WORD
filters: filters:
- multiply: 0.5 - multiply: 0.5