select:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Betriebsart"
id: ${lower_name}_HK1_Betriebsart
address: 8046
value_type: U_WORD
optionsmap:
"Aus": 0
"Automatik": 1
"Extraheizen": 2
"Absenken": 3
"Dauerabsenken": 4
"Partybetrieb": 5
sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Vorlauf-Isttemperatur"
id: ${lower_name}_HK1_Vorlauf_Isttemperatur
register_type: read
address: 1030 #Wrong ?
unit_of_measurement: "°C"
device_class: temperature
state_class: measurement
value_type: S_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Vorlauf-Solltemperatur"
id: ${lower_name}_HK1_Vorlauf_Solltemperatur
register_type: read
address: 1031 #Wrong ?
unit_of_measurement: "°C"
value_type: S_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Raumtemperatur"
id: ${lower_name}_HK1_Raumtemperatur
register_type: read
address: 1032 #Wrong ?
unit_of_measurement: "°C"
value_type: S_WORD
filters:
- multiply: 0.5
binary_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Pumpe AN AUS"
id: ${lower_name}_HK1_Pumpe_AN_AUS
register_type: coil
address: 1029
number:
# not correct yet ?
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
id: ${lower_name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1032
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 10
max_value: 110
# not correct yet ?
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
id: ${lower_name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1031
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 10
max_value: 110
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
id: ${lower_name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1039
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 10
max_value: 30
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Absenkung der Vorlauftemperatur im Absenkbetrieb"
id: ${lower_name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1033
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 0
max_value: 70
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Gewünschte Raumtemperatur während des Heizbetriebs"
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1035
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 10
max_value: 30
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Gewünschte Raumtemperatur während des Absenkbetriebes"
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1040
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 10
max_value: 30
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1036
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: -20
max_value: 50
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1037
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: -20
max_value: 50
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Frostschutztemperatur"
id: ${lower_name}_HK1_Frostschutztemperatur
address: 1038
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: -10
max_value: 20
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
device_id: ${device_id}
name: "Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
id: ${lower_name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1047
entity_category: config
unit_of_measurement: "°C"
value_type: S_WORD
min_value: 60
max_value: 120