438 lines
14 KiB
YAML
438 lines
14 KiB
YAML
esphome:
|
|
name: wemos-d1-froeling
|
|
friendly_name: wemos-d1-froeling
|
|
|
|
esp8266:
|
|
board: d1_mini
|
|
|
|
# Enable logging
|
|
logger:
|
|
level: INFO
|
|
|
|
# Enable Home Assistant API
|
|
api:
|
|
encryption:
|
|
key: ""
|
|
|
|
ota:
|
|
password: ""
|
|
|
|
wifi:
|
|
ssid: !secret wifi_ssid
|
|
password: !secret wifi_password
|
|
|
|
web_server:
|
|
port: 80
|
|
|
|
substitutions:
|
|
name: froeling
|
|
modbus_controller_id: froeling
|
|
|
|
uart:
|
|
- id: uartfroeling
|
|
tx_pin: 15
|
|
rx_pin: 13
|
|
baud_rate: 57600
|
|
data_bits: 8
|
|
stop_bits: 1
|
|
parity: NONE
|
|
#debug:
|
|
|
|
modbus:
|
|
id: modbus1
|
|
uart_id: uartfroeling
|
|
|
|
modbus_controller:
|
|
- id: froeling
|
|
address: 2
|
|
modbus_id: modbus1
|
|
setup_priority: -10
|
|
update_interval: "8s"
|
|
command_throttle: "50ms"
|
|
|
|
globals:
|
|
- id: debug_address
|
|
type: int
|
|
restore_value: yes
|
|
initial_value: '0'
|
|
|
|
switch:
|
|
- platform: restart
|
|
name: "Restart wemos-d1-froeling"
|
|
|
|
sensor:
|
|
##### Kessel #####
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Kesseltemperatur"
|
|
id: ${name}_Kesseltemperatur
|
|
register_type: read
|
|
address: 0
|
|
unit_of_measurement: "°C"
|
|
accuracy_decimals: 1
|
|
value_type: U_WORD
|
|
filters:
|
|
- multiply: 0.5
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Abgastemperatur"
|
|
id: ${name}_Abgastemperatur
|
|
register_type: read
|
|
address: 1
|
|
unit_of_measurement: "°C"
|
|
accuracy_decimals: 1
|
|
value_type: U_WORD
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Verbleibende Heizstunden bis zur Asche entleeren Warnung"
|
|
id: ${name}_Verbleibende_Heizstunden_bis_zur_Asche_entleeren_Warnung
|
|
register_type: read
|
|
address: 86
|
|
unit_of_measurement: "h"
|
|
value_type: U_WORD
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Saugzug - Ansteuerung"
|
|
id: ${name}_Saugzug_Ansteuerung
|
|
register_type: read
|
|
address: 75
|
|
unit_of_measurement: "%"
|
|
value_type: U_WORD
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Restsauerstoffgehalt"
|
|
id: ${name}_Restsauerstoffgehalt
|
|
register_type: read
|
|
address: 3
|
|
unit_of_measurement: "%"
|
|
accuracy_decimals: 1
|
|
value_type: U_WORD
|
|
filters:
|
|
- multiply: 0.1
|
|
|
|
##### Heizkörper HK1 #####
|
|
# - platform: modbus_controller
|
|
# modbus_controller_id: ${modbus_controller_id}
|
|
# name: "${name}-HK1 - Vorlauf-Isttemperatur"
|
|
# id: ${name}_HK1_Vorlauf_Isttemperatur
|
|
# register_type: read
|
|
# address: 1030
|
|
# unit_of_measurement: "°C"
|
|
# value_type: U_WORD
|
|
# filters:
|
|
# - multiply: 0.5
|
|
|
|
# - platform: modbus_controller
|
|
# modbus_controller_id: ${modbus_controller_id}
|
|
# name: "${name}-HK1 - Vorlauf-Solltemperatur"
|
|
# id: ${name}_HK1_Vorlauf_Solltemperatur
|
|
# register_type: read
|
|
# address: 1031
|
|
# unit_of_measurement: "°C"
|
|
# value_type: U_WORD
|
|
# filters:
|
|
# - multiply: 0.5
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Aussentemperatur"
|
|
id: ${name}_Aussentemperatur
|
|
register_type: read
|
|
address: 1000
|
|
unit_of_measurement: "°C"
|
|
value_type: U_WORD
|
|
filters:
|
|
- multiply: 0.5
|
|
|
|
##### Boiler 1 #####
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Boiler 1 Temperatur oben"
|
|
id: ${name}_Boiler_1_Temperatur_oben
|
|
register_type: read
|
|
address: 1630
|
|
unit_of_measurement: "°C"
|
|
value_type: U_WORD
|
|
filters:
|
|
- multiply: 0.5
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Boiler 1 Pumpe Ansteuerung"
|
|
id: ${name}_Boiler_1_Pumpe_Ansteuerung
|
|
register_type: read
|
|
address: 1632
|
|
unit_of_measurement: "%"
|
|
value_type: U_WORD
|
|
|
|
##### Puffer 1 #####
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Puffer 1 Temperatur oben"
|
|
id: ${name}_Puffer_1_Temperatur_oben
|
|
register_type: read
|
|
address: 2000
|
|
unit_of_measurement: "°C"
|
|
value_type: U_WORD
|
|
filters:
|
|
- multiply: 0.5
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Puffer 1 Temperatur mitte"
|
|
id: ${name}_Puffer_1_Temperatur_mitte
|
|
register_type: read
|
|
address: 2001
|
|
unit_of_measurement: "°C"
|
|
value_type: U_WORD
|
|
filters:
|
|
- multiply: 0.5
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Puffer 1 Temperatur unten"
|
|
id: ${name}_Puffer_1_Temperatur_unten
|
|
register_type: read
|
|
address: 2002
|
|
unit_of_measurement: "°C"
|
|
value_type: U_WORD
|
|
filters:
|
|
- multiply: 0.5
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Puffer 1 Ladezustand"
|
|
id: ${name}_Puffer_1_Ladezustand
|
|
register_type: read
|
|
address: 2006
|
|
unit_of_measurement: "%"
|
|
value_type: U_WORD
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Puffer 1 Pufferpumpen Ansteuerung"
|
|
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung
|
|
register_type: read
|
|
address: 2003
|
|
unit_of_measurement: "%"
|
|
value_type: U_WORD
|
|
|
|
##### Austragung #####
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Fuellstand im Pelletsbehaelter"
|
|
id: ${name}_Fuellstand_im_Pelletsbehaelter
|
|
register_type: read
|
|
address: 21
|
|
unit_of_measurement: "%"
|
|
accuracy_decimals: 1
|
|
value_type: U_WORD
|
|
filters:
|
|
- multiply: 0.0048309178743961
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Resetierbarer kg-Zaehler"
|
|
id: ${name}_Resetierbarer_kg_Zaehler
|
|
register_type: read
|
|
address: 81
|
|
unit_of_measurement: "kg"
|
|
value_type: U_WORD
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Resetierbarer t-Zaehler"
|
|
id: ${name}_Resetierbarer_t_Zaehler
|
|
register_type: read
|
|
address: 82
|
|
unit_of_measurement: "t"
|
|
value_type: U_WORD
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Pelletverbrauch Gesamt"
|
|
id: ${name}_Pelletverbrauch_Gesamt
|
|
register_type: read
|
|
address: 83
|
|
unit_of_measurement: "t"
|
|
accuracy_decimals: 1
|
|
value_type: U_WORD
|
|
filters:
|
|
- multiply: 0.1
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Pelletlager Restbestand"
|
|
id: ${name}_Pelletlager_Restbestand
|
|
register_type: holding
|
|
address: 319
|
|
unit_of_measurement: "t"
|
|
accuracy_decimals: 1
|
|
value_type: U_WORD
|
|
filters:
|
|
- multiply: 0.1
|
|
|
|
# #### Zirkulations Pumpe #####
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Ruecklauftemperatur an der Zirkulations Leitung"
|
|
id: ${name}_Ruecklauftemperatur_an_der_Zirkulations_Leitung
|
|
register_type: read
|
|
address: 711
|
|
unit_of_measurement: "°C"
|
|
value_type: U_WORD
|
|
filters:
|
|
- multiply: 0.5
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Strömungsschalter an der Brauchwasser Leitung"
|
|
id: ${name}_Stoemungsschalter_an_der_Brauchwasser_Leitung
|
|
register_type: read
|
|
address: 600
|
|
value_type: U_WORD
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Drehzahl der Zirkulations Pumpe"
|
|
id: ${name}_Drehzahl_der_Zirkulations_Pumpe
|
|
register_type: read
|
|
address: 710
|
|
unit_of_measurement: "%"
|
|
value_type: U_WORD
|
|
|
|
number:
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Bei welcher RL Temperatur an der Zirkulationsleitung soll die Pumpe ausschalten"
|
|
id: ${name}_Bei_welcher_RL_Temperatur_an_der_Zirkulationsleitung_soll_die_Pumpe_ausschalten
|
|
address: 600
|
|
unit_of_measurement: "°C"
|
|
value_type: U_WORD
|
|
multiply: 2
|
|
|
|
text_sensor:
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Anlagenzustand"
|
|
id: ${name}_Anlagenzustand
|
|
register_type: read
|
|
address: 4000
|
|
raw_encode: HEXBYTES
|
|
lambda: |-
|
|
uint16_t value = modbus_controller::word_from_hex_str(x, 0);
|
|
switch (value) {
|
|
case 0: return std::string("Dauerlast");
|
|
case 1: return std::string("Brauchwasser");
|
|
case 2: return std::string("Automatik");
|
|
case 3: return std::string("Scheitholzbetrieb");
|
|
case 4: return std::string("Reinigen");
|
|
case 5: return std::string("Ausgeschaltet");
|
|
case 6: return std::string("Extraheizen");
|
|
case 7: return std::string("Kaminkehrer");
|
|
case 8: return std::string("Reinigen");
|
|
default: return std::string("----");
|
|
}
|
|
return x;
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${name}-Kesselzustand"
|
|
id: ${name}_Kesselzustand
|
|
register_type: read
|
|
address: 4001
|
|
raw_encode: HEXBYTES
|
|
lambda: |-
|
|
uint16_t value = modbus_controller::word_from_hex_str(x, 0);
|
|
switch (value) {
|
|
case 0: return std::string("STÖRUNG");
|
|
case 1: return std::string("Kessel Aus");
|
|
case 2: return std::string("Anheizen");
|
|
case 3: return std::string("Heizen");
|
|
case 4: return std::string("Feuererhaltung");
|
|
case 5: return std::string("Feuer Aus");
|
|
case 6: return std::string("Tür offen");
|
|
case 7: return std::string("Vorbereitung");
|
|
case 8: return std::string("Vorwärmen");
|
|
case 9: return std::string("Zünden");
|
|
case 10: return std::string("Abstellen Warten");
|
|
case 11: return std::string("Abstellen Warten1");
|
|
case 12: return std::string("Abstellen Einschub1");
|
|
case 13: return std::string("Abstellen Warten2");
|
|
case 14: return std::string("Abstellen Einschub2");
|
|
case 15: return std::string("Abreinigen");
|
|
case 16: return std::string("2h warten");
|
|
case 17: return std::string("Saugen / Heizen");
|
|
case 18: return std::string("Fehlzündung");
|
|
case 19: return std::string("Betriebsbereit");
|
|
case 20: return std::string("Rost schließen");
|
|
case 21: return std::string("Stoker leeren");
|
|
case 22: return std::string("Vorheizen");
|
|
case 23: return std::string("Saugen");
|
|
case 24: return std::string("RSE schließen");
|
|
case 25: return std::string("RSE öffnen");
|
|
case 26: return std::string("Rost kippen");
|
|
case 27: return std::string("Vorwärmen-Zünden");
|
|
case 28: return std::string("Resteinschub");
|
|
case 29: return std::string("Stoker auffüllen");
|
|
case 30: return std::string("Lambdasonde aufheizen");
|
|
case 31: return std::string("Gebläsenachlauf I");
|
|
case 32: return std::string("Gebläsenachlauf II");
|
|
case 33: return std::string("Abgestellt");
|
|
case 34: return std::string("Nachzünden");
|
|
case 35: return std::string("Zünden Warten");
|
|
case 36: return std::string("FB: RSE schließen");
|
|
case 37: return std::string("FB: Kessel belüften");
|
|
case 38: return std::string("FB: Zünden");
|
|
case 39: return std::string("FB: min. Einschub");
|
|
case 40: return std::string("RSE schließen");
|
|
case 41: return std::string("STÖRUNG: STB/NA");
|
|
case 42: return std::string("STÖRUNG: Kipprost");
|
|
case 43: return std::string("STÖRUNG: FR-Überdr.");
|
|
case 44: return std::string("STÖRUNG: Türkont.");
|
|
case 45: return std::string("STÖRUNG: Saugzug");
|
|
case 46: return std::string("STÖRUNG: Umfeld");
|
|
case 47: return std::string("FEHLER: STB/NA");
|
|
case 48: return std::string("FEHLER: Kipprost");
|
|
case 49: return std::string("FEHLER: FR-Überdr.");
|
|
case 50: return std::string("FEHLER: Türkont.");
|
|
case 51: return std::string("FEHLER: Saugzug");
|
|
case 52: return std::string("FEHLER: Umfeld");
|
|
case 53: return std::string("FEHLER: Stoker");
|
|
case 54: return std::string("STÖRUNG: Stoker");
|
|
case 55: return std::string("FB: Stoker leeren");
|
|
case 56: return std::string("Vorbelüften");
|
|
case 57: return std::string("STÖRUNG: Hackgut");
|
|
case 58: return std::string("FEHLER: Hackgut");
|
|
case 59: return std::string("NB: Tür offen");
|
|
case 60: return std::string("NB: Anheizen");
|
|
case 61: return std::string("NB: Heizen");
|
|
case 62: return std::string("FEHLER: STB/NA");
|
|
case 63: return std::string("FEHLER: Allgemein");
|
|
case 64: return std::string("NB: Feuer Aus");
|
|
case 65: return std::string("Selbsttest aktiv");
|
|
case 66: return std::string("Fehlerbeh. 20min");
|
|
case 67: return std::string("FEHLER: Fallschacht");
|
|
case 68: return std::string("STÖRUNG: Fallschacht");
|
|
case 69: return std::string("Reinigen möglich");
|
|
case 70: return std::string("Heizen - Reinigen");
|
|
case 71: return std::string("SH Anheizen");
|
|
case 72: return std::string("SH Heizen");
|
|
case 73: return std::string("SH Heiz/Abstell");
|
|
case 74: return std::string("STÖRUNG sicher");
|
|
case 75: return std::string("AGR Nachlauf");
|
|
case 76: return std::string("AGR reinigen");
|
|
case 77: return std::string("Zündung AUS");
|
|
case 78: return std::string("Filter reinigen");
|
|
case 79: return std::string("Anheizassistent");
|
|
case 80: return std::string("SH Zünden");
|
|
case 81: return std::string("SH Störung");
|
|
case 82: return std::string("Sensorcheck");
|
|
default: return std::string("----");
|
|
}
|
|
return x;
|