select:
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Betriebsart"
|
|
id: ${lower_name}_HK4_Betriebsart
|
|
address: 8049
|
|
value_type: U_WORD
|
|
optionsmap:
|
|
"Aus": 0
|
|
"Automatik": 1
|
|
"Extraheizen": 2
|
|
"Absenken": 3
|
|
"Dauerabsenken": 4
|
|
"Partybetrieb": 5
|
|
|
|
sensor:
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Vorlauf-Isttemperatur"
|
|
id: ${lower_name}_HK4_Vorlauf_Isttemperatur
|
|
register_type: read
|
|
address: 1120 #Wrong ?
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
filters:
|
|
- multiply: 0.5
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Vorlauf-Solltemperatur"
|
|
id: ${lower_name}_HK4_Vorlauf_Solltemperatur
|
|
register_type: read
|
|
address: 1121 #Wrong ?
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
filters:
|
|
- multiply: 0.5
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Raumtemperatur"
|
|
id: ${lower_name}_HK4_Raumtemperatur
|
|
register_type: read
|
|
address: 1122 #Wrong ?
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
filters:
|
|
- multiply: 0.5
|
|
|
|
binary_sensor:
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Pumpe AN AUS"
|
|
id: ${lower_name}_HK4_Pumpe_AN_AUS
|
|
register_type: coil
|
|
address: 1120
|
|
|
|
number:
|
|
# not correct yet ?
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
|
id: ${lower_name}_HK4_Vorlauf_Temperatur_10C_Aussentemperatur
|
|
address: 1121
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
multiply: 2
|
|
min_value: 10
|
|
max_value: 110
|
|
|
|
# not correct yet ?
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
|
id: ${lower_name}_HK4_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
|
address: 1122
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
multiply: 2
|
|
min_value: 10
|
|
max_value: 110
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
|
id: ${lower_name}_HK4_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
|
address: 1123
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
multiply: 2
|
|
min_value: 0
|
|
max_value: 70
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
|
id: ${lower_name}_HK4_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
|
address: 1129
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
multiply: 2
|
|
min_value: 10
|
|
max_value: 30
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
|
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
|
address: 1125
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
multiply: 2
|
|
min_value: 10
|
|
max_value: 30
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
|
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
|
address: 1130
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
multiply: 2
|
|
min_value: 10
|
|
max_value: 30
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
|
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
|
address: 1126
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
multiply: 2
|
|
min_value: -20
|
|
max_value: 50
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
|
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
|
address: 1127
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
multiply: 2
|
|
min_value: -20
|
|
max_value: 50
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Frostschutztemperatur"
|
|
id: ${lower_name}_HK4_Frostschutztemperatur
|
|
address: 1128
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
multiply: 2
|
|
min_value: -10
|
|
max_value: 20
|
|
|
|
- platform: modbus_controller
|
|
modbus_controller_id: ${modbus_controller_id}
|
|
name: "${hk4_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
|
id: ${lower_name}_HK4_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
|
address: 1135
|
|
unit_of_measurement: "°C"
|
|
value_type: S_WORD
|
|
min_value: 60
|
|
max_value: 120
|