Files
Lambdatronic_S3200/heizkreis_02.yaml
Florian Simmer 2a038f0088 Change id
2024-03-22 18:33:54 +01:00

169 lines
5.1 KiB
YAML

select:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Betriebsart"
id: ${lower_name}_HK2_Betriebsart
address: 8047
value_type: U_WORD
optionsmap:
"Aus": 0
"Automatik": 1
"Extraheizen": 2
"Absenken": 3
"Dauerabsenken": 4
"Partybetrieb": 5
sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Vorlauf-Isttemperatur"
id: ${lower_name}_HK2_Vorlauf_Isttemperatur
register_type: read
address: 1060 #Wrong ?
unit_of_measurement: "°C"
value_type: S_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Vorlauf-Solltemperatur"
id: ${lower_name}_HK2_Vorlauf_Solltemperatur
register_type: read
address: 1061 #Wrong ?
unit_of_measurement: "°C"
value_type: S_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Raumtemperatur"
id: ${lower_name}_HK2_Raumtemperatur
register_type: read
address: 1062 #Wrong ?
unit_of_measurement: "°C"
value_type: S_WORD
filters:
- multiply: 0.5
binary_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Pumpe AN AUS"
id: ${lower_name}_HK2_Pumpe_AN_AUS
register_type: coil
address: 1059
number:
# not correct yet ?
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
id: ${lower_name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1061
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 10
max_value: 110
# not correct yet ?
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
id: ${lower_name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1062
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 10
max_value: 110
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
id: ${lower_name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1063
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 0
max_value: 70
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
id: ${lower_name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1069
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 10
max_value: 30
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1065
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 10
max_value: 30
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1070
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: 10
max_value: 30
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1066
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: -20
max_value: 50
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1067
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: -20
max_value: 50
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Frostschutztemperatur"
id: ${lower_name}_HK2_Frostschutztemperatur
address: 1068
unit_of_measurement: "°C"
value_type: S_WORD
multiply: 2
min_value: -10
max_value: 20
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
id: ${lower_name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1078
unit_of_measurement: "°C"
value_type: S_WORD
min_value: 60
max_value: 120