sensor: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} name: "${boiler1_name} Temperatur oben" id: ${name}_Boiler_1_Temperatur_oben register_type: read address: 1630 unit_of_measurement: "°C" value_type: U_WORD filters: - multiply: 0.5 - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} name: "${boiler1_name} Pumpe Ansteuerung" id: ${name}_Boiler_1_Pumpe_Ansteuerung register_type: read address: 1632 unit_of_measurement: "%" value_type: U_WORD number: - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} name: "${boiler1_name} Gewünschte Boilertemperatur" id: ${name}_Boiler_1_Gewuenschte_Boilertemperatur address: 1631 unit_of_measurement: "°C" value_type: U_WORD multiply: 2 min_value: 10 max_value: 100 - platform: modbus_controller modbus_controller_id: ${modbus_controller_id} name: "${boiler1_name} Nachladen, wenn Boilertemperatur unter" id: ${name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter address: 1632 unit_of_measurement: "°C" value_type: U_WORD multiply: 2 min_value: 1 max_value: 90 binary_sensor: - platform: template name: "${boiler1_name} Pumpe Ansteuerung AN AUS" id: ${name}_Boiler_1_Pumpe_Ansteuerung_AN_AUS lambda: |- if (id(${name}_Boiler_1_Pumpe_Ansteuerung).state > 0) { return true; } else { return false; }