asd
This commit is contained in:
1 parent
270ef18bd4
commit
c3126a1421
6 files changed
+1003
-13
No files matched your search
+23
-2
@@ -53,8 +53,7 @@ binary_sensor:
|
||||
name: "${hk1_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK1_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
#address: 999 # Heizkreispumpe 0
|
||||
address: 1029 # Heizkreispumpe 1 - wrong ?
|
||||
address: 1029
|
||||
|
||||
number:
|
||||
# not correct yet ?
|
||||
@@ -103,6 +102,28 @@ number:
|
||||
min_value: 0
|
||||
max_value: 70
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${name}_HK1_Gewuenschte_Raumtemperatur_während_des_Heizbetriebs
|
||||
address: 1035
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 30
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${name}_HK1_Gewuenschte_Raumtemperatur_während_des_Absenkbetriebes
|
||||
address: 1040
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 30
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
|
||||
Reference in new issue