- split up esphome yaml file into muliple pieces for better overview (packages)
- switched to ESP32 board (esp8266 reached OOM) - added few new entities - added Graphical Dashboard "Heizkörper"
This commit is contained in:
@@ -23,10 +23,10 @@
|
||||
inkscape:deskcolor="#d1d1d1"
|
||||
inkscape:zoom="1.1351589"
|
||||
inkscape:cx="218.91208"
|
||||
inkscape:cy="222.87628"
|
||||
inkscape:cy="222.87629"
|
||||
inkscape:window-width="958"
|
||||
inkscape:window-height="1128"
|
||||
inkscape:window-x="953"
|
||||
inkscape:window-x="946"
|
||||
inkscape:window-y="0"
|
||||
inkscape:window-maximized="0"
|
||||
inkscape:current-layer="Ebene_1" /> <defs
|
||||
@@ -63,8 +63,9 @@
|
||||
id="path5" /> <path
|
||||
d="M252.9,209.1l-3.4,35.2c-0.5,5.3-8.8,4.6-8.3-0.7l3.4-35.2C245.1,203,253.4,203.8,252.9,209.1z"
|
||||
id="path6" /> </g> <g
|
||||
id="sensor.froeling_hk1_pumpe_an_aus"
|
||||
class="stPumpActive"><title
|
||||
id="binary_sensor.froeling_hk1_pumpe_an_aus"
|
||||
class="stPumpActive"
|
||||
inkscape:label="binary_sensor.froeling_hk1_pumpe_an_aus"><title
|
||||
id="title6">Heizkreispumpe</title> <path
|
||||
d="M71.1,212.4c0-1.9,1.5-3.4,3.4-3.4c1.9,0,3.4,1.5,3.4,3.4c0,1.9-1.5,3.4-3.4,3.4 C72.7,215.8,71.1,214.3,71.1,212.4z"
|
||||
id="path7" /> <path
|
||||
|
||||
|
Before Width: | Height: | Size: 12 KiB After Width: | Height: | Size: 12 KiB |
@@ -27,7 +27,7 @@
|
||||
inkscape:cy="169.13932"
|
||||
inkscape:window-width="958"
|
||||
inkscape:window-height="1128"
|
||||
inkscape:window-x="953"
|
||||
inkscape:window-x="946"
|
||||
inkscape:window-y="0"
|
||||
inkscape:window-maximized="0"
|
||||
inkscape:current-layer="Ebene_1" /> <defs
|
||||
@@ -2589,7 +2589,8 @@
|
||||
r="0.8"
|
||||
id="circle508" /> </g> </g> </g> <g
|
||||
id="binary_sensor.froeling_puffer_1_pufferpumpen_ansteuerung_an_aus"
|
||||
class="stPumpInActive"><title
|
||||
class="stPumpInActive"
|
||||
inkscape:label="binary_sensor.froeling_puffer_1_pufferpumpen_ansteuerung_an_aus"><title
|
||||
id="title508">Aktueller Status der Pufferpumpe</title> <path
|
||||
d="M293.6,184.5c0-1.8-1.5-3.3-3.3-3.3c-1.8,0-3.3,1.5-3.3,3.3c0,1.8,1.5,3.3,3.3,3.3 C292.1,187.8,293.6,186.3,293.6,184.5z"
|
||||
id="path508" /> <path
|
||||
@@ -2605,8 +2606,9 @@
|
||||
id="path513" /> <path
|
||||
d="M299.9,184.5c0-5.4-4.3-9.7-9.6-9.7c-5.3,0-9.6,4.3-9.6,9.7c0,5.4,4.3,9.7,9.6,9.7 C295.6,194.2,299.9,189.9,299.9,184.5z M283.1,184.5c0-4,3.2-7.2,7.2-7.2c4,0,7.2,3.2,7.2,7.2c0,4-3.2,7.2-7.2,7.2 C286.3,191.7,283.1,188.5,283.1,184.5z"
|
||||
id="path514" /> </g> <g
|
||||
id="binary_sensor.froeling_kesselzustand_heizen"
|
||||
class="stHeatingOff"><title
|
||||
id="sensor.froeling_kesselzustand"
|
||||
class="stHeatingOff"
|
||||
inkscape:label="sensor.froeling_kesselzustand"><title
|
||||
id="title514">Betriebszustand</title> <path
|
||||
d="M143.6,171.7c0.4,4.9,3.7,11.8,12.3,10c-3.6-1-6.5-4.3-7.7-10.4c0.8,0.2,1.9,0.9,2.3,1.1 c-0.2-0.9,0.1-3.4,1.4-6.4c1.5,7.7,2.6,9,4.1,9.3c-1.4-3.7-1.3-6.9-0.1-9.4c0.6,2.4,1.8,4.2,2.9,5.4c1.8-2.2,2.6-5.1,1.8-11.4 c4,5.3,3.7,8.6,2.4,10.6c1.1-0.3,2.7-1.8,3.8-4.4c1,1.2,0.8,3.4-0.1,5.9c0.6-0.2,1.6-0.6,2.2-1.1c-1,7.3-5.2,8.2-9.2,10.4 c5.7,2.3,15.1-1.1,16.2-8.8c0.3-1.3-0.1-3.2-0.4-4.7c-0.6,1-0.9,2.3-1.8,2.8c-0.2-1.4,0.2-2.6,0.8-3.8c1.1-4.3,0.4-7.9-1.9-10.7 c-0.4,2.1-0.9,3.9-1.9,4.4c-1.1-6.5-3.1-11-5.5-12.2c0.2,1.9,0.1,3.5-0.6,4.9c-2-7.2-5.5-6.7-6.5-13.2c-1,0.7-1.2,2.3-1.4,3.7 c0,2.9,0.2,5.7-1,7.1c-1.1-2.1-2.1-3.8-3.9-4c1.3,2.7,0.8,7.4-1.1,12.5c-0.7-1.3-1.9-3.9-3.6-4.3c0.4,3.4-0.1,7.3-0.9,10.9 c-0.5-0.8-1.5-1.7-2.6-2.3C144.8,166.8,143.1,168.2,143.6,171.7z M159.2,149.8c0.2,2.7,0,5.5-0.8,6.9 C158.3,154.1,158,152.6,159.2,149.8z"
|
||||
id="path515" /> </g> <g
|
||||
@@ -2635,7 +2637,8 @@
|
||||
id="polyline519" /> </g> </g> </g> <text
|
||||
id="sensor.froeling_verbleibende_heizstunden_bis_zur_asche_entleeren_warnung"
|
||||
transform="matrix(1 0 0 1 80 231.4438)"
|
||||
class="st9 st10 st11">17h</text> <g
|
||||
class="st9 st10 st11"
|
||||
inkscape:label="sensor.froeling_verbleibende_heizstunden_bis_zur_asche_entleeren_warnung">17h</text> <g
|
||||
id="label_fuel-level"><title
|
||||
id="title519">Restbestand im Brennstofflagerraum</title> <path
|
||||
id="frame_1_"
|
||||
@@ -2660,7 +2663,8 @@
|
||||
id="path522" /> </g> </g> </g> <text
|
||||
id="sensor.froeling_fuellstand_im_pelletsbehaelter"
|
||||
transform="matrix(1 0 0 1 80 47.6704)"
|
||||
class="st9 st10 st11">32%</text> <g
|
||||
class="st9 st10 st11"
|
||||
inkscape:label="sensor.froeling_fuellstand_im_pelletsbehaelter">32%</text> <g
|
||||
id="Saugzug_Ansteuerung"><title
|
||||
id="title522">Drehzahl des Saugzuggebläses</title> <path
|
||||
id="frame_2_"
|
||||
@@ -2745,7 +2749,8 @@
|
||||
id="rect530" /> </g> </g> </g> <text
|
||||
id="sensor.froeling_abgastemperatur"
|
||||
transform="matrix(1 0 0 1 207.5 47.2747)"
|
||||
class="st9 st10 st11">57°C</text> <g
|
||||
class="st9 st10 st11"
|
||||
inkscape:label="sensor.froeling_abgastemperatur">57°C</text> <g
|
||||
id="label_lambda"><title
|
||||
id="title530">Restsauerstoffgehalt</title> <path
|
||||
id="frame_3_"
|
||||
|
||||
|
Before Width: | Height: | Size: 62 KiB After Width: | Height: | Size: 62 KiB |
@@ -59,25 +59,21 @@ g.floorplan-long-click > :not(text):hover,
|
||||
transition: fill 5s ease;
|
||||
}
|
||||
|
||||
.binary-sensor-kesselzustand-heizen-an {
|
||||
.fill-red {
|
||||
fill: #ff0000 !important;
|
||||
fill-opacity: 1 !important;
|
||||
}
|
||||
|
||||
.binary-sensor-kesselzustand-heizen-aus {
|
||||
.fill-grey {
|
||||
fill: #9e9e9e !important;
|
||||
transition: fill 5s ease;
|
||||
}
|
||||
|
||||
.binary-sensor-puffer-1-pufferpumpen-ansteuerung-an {
|
||||
.fill-green {
|
||||
fill: #00c800 !important;
|
||||
fill-opacity: 1 !important;
|
||||
}
|
||||
|
||||
.binary-sensor-puffer-1-pufferpumpen-ansteuerung-aus {
|
||||
fill: #9e9e9e !important;
|
||||
transition: fill 5s ease;
|
||||
}
|
||||
|
||||
|
||||
/* Buttons */
|
||||
|
||||
Reference in New Issue
Block a user