- split up esphome yaml file into muliple pieces for better overview (packages)

- switched to ESP32 board (esp8266 reached OOM)
- added few new entities
- added Graphical Dashboard "Heizkörper"
This commit is contained in:
GyroGearl00se committed 2023-11-17 01:39:08 +01:00
1 parent 5022eac1d8
commit 8ce8162385
14 files changed
+850 -572

No files matched your search

+54
View File
@@ -0,0 +1,54 @@
sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Fuellstand im Pelletsbehaelter"
id: ${name}_Fuellstand_im_Pelletsbehaelter
register_type: read
address: 21
unit_of_measurement: "%"
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.0048309178743961
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Resetierbarer kg-Zaehler"
id: ${name}_Resetierbarer_kg_Zaehler
register_type: read
address: 81
unit_of_measurement: "kg"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Resetierbarer t-Zaehler"
id: ${name}_Resetierbarer_t_Zaehler
register_type: read
address: 82
unit_of_measurement: "t"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Pelletverbrauch Gesamt"
id: ${name}_Pelletverbrauch_Gesamt
register_type: read
address: 83
unit_of_measurement: "t"
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Pelletlager Restbestand"
id: ${name}_Pelletlager_Restbestand
register_type: holding
address: 319
unit_of_measurement: "t"
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.1
+43
View File
@@ -0,0 +1,43 @@
sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Boiler 1 Temperatur oben"
id: ${name}_Boiler_1_Temperatur_oben
register_type: read
address: 1630
unit_of_measurement: "°C"
value_type: U_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Boiler 1 Pumpe Ansteuerung"
id: ${name}_Boiler_1_Pumpe_Ansteuerung
register_type: read
address: 1632
unit_of_measurement: "%"
value_type: U_WORD
number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Boiler 1 Gewünschte Boilertemperatur"
id: ${name}_Boiler_1_Gewuenschte_Boilertemperatur
address: 1631
unit_of_measurement: "°C"
value_type: U_WORD
multiply: 2
min_value: 10
max_value: 100
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Boiler 1 Nachladen, wenn Boilertemperatur unter"
id: ${name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
address: 1632
unit_of_measurement: "°C"
value_type: U_WORD
multiply: 2
min_value: 1
max_value: 90
+134
View File
@@ -0,0 +1,134 @@
sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} HK1 - Vorlauf-Isttemperatur"
id: ${name}_HK1_Vorlauf_Isttemperatur
register_type: read
address: 1030 #Wrong ?
unit_of_measurement: "°C"
value_type: U_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} HK1 - Vorlauf-Solltemperatur"
id: ${name}_HK1_Vorlauf_Solltemperatur
register_type: read
address: 1031 #Wrong ?
unit_of_measurement: "°C"
value_type: U_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Aussentemperatur"
id: ${name}_Aussentemperatur
register_type: read
address: 1000
unit_of_measurement: "°C"
value_type: U_WORD
filters:
- multiply: 0.5
binary_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} HK1 - Pumpe AN AUS"
id: ${name}_HK1_Pumpe_AN_AUS
register_type: coil
#address: 999 # Heizkreispumpe 0
address: 1029 # Heizkreispumpe 1 - wrong ?
number:
# not correct yet ?
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} HK1 - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
id: ${name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1032
unit_of_measurement: "°C"
value_type: U_WORD
multiply: 2
min_value: 10
max_value: 110
# not correct yet ?
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} HK1 - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
id: ${name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1031
unit_of_measurement: "°C"
value_type: U_WORD
multiply: 2
min_value: 10
max_value: 110
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} HK1 - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
id: ${name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1039
unit_of_measurement: "°C"
value_type: U_WORD
multiply: 2
min_value: 10
max_value: 30
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} HK1 - Absenkung der Vorlauftemperatur im Absenkbetrieb"
id: ${name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1033
unit_of_measurement: "°C"
value_type: U_WORD
multiply: 2
min_value: 0
max_value: 70
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} HK1 - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb
einschaltet"
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1036
unit_of_measurement: "°C"
value_type: U_WORD
multiply: 2
min_value: -20
max_value: 50
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} HK1 - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb
einschaltet"
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1037
unit_of_measurement: "°C"
value_type: U_WORD
multiply: 2
min_value: -20
max_value: 50
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} HK1 - Frostschutztemperatur"
id: ${name}_HK1_Frostschutztemperatur
address: 1038
unit_of_measurement: "°C"
value_type: U_WORD
multiply: 2
min_value: -10
max_value: 20
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} HK1 - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
id: ${name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1047
unit_of_measurement: "°C"
value_type: U_WORD
min_value: 60
max_value: 120
+135
View File
@@ -0,0 +1,135 @@
sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Kesseltemperatur"
id: ${name}_Kesseltemperatur
register_type: read
address: 0
unit_of_measurement: "°C"
value_type: U_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Abgastemperatur"
id: ${name}_Abgastemperatur
register_type: read
address: 1
unit_of_measurement: "°C"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Verbleibende Heizstunden bis zur Asche entleeren Warnung"
id: ${name}_Verbleibende_Heizstunden_bis_zur_Asche_entleeren_Warnung
register_type: read
address: 86
unit_of_measurement: "h"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Saugzug - Ansteuerung"
id: ${name}_Saugzug_Ansteuerung
register_type: read
address: 12
unit_of_measurement: "%"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Saugzugdrehzahl"
id: ${name}_Saugzugdrehzahl
register_type: read
address: 6
unit_of_measurement: "rpm"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Sauerstoffregler"
id: ${name}_Sauerstoffregler
register_type: read
address: 16
unit_of_measurement: "%"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Restsauerstoffgehalt"
id: ${name}_Restsauerstoffgehalt
register_type: read
address: 3
unit_of_measurement: "%"
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Rücklauffühler"
id: ${name}_Ruecklauffuehler
register_type: read
address: 9
unit_of_measurement: "°C"
value_type: U_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Primärluft"
id: ${name}_Primaerluft
register_type: read
address: 11
unit_of_measurement: "%"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Sekundärluft"
id: ${name}_Sekundaerluft
register_type: read
address: 13
unit_of_measurement: "%"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Betriebsstunden"
id: ${name}_Betriebsstunden
register_type: read
address: 20
unit_of_measurement: "h"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Stunden seit letzter Wartung"
id: ${name}_Stunden_seit_letzter_Wartung
register_type: read
address: 55
unit_of_measurement: "h"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Betriebsstunden in der Feuererhaltung"
id: ${name}_Betriebsstunden_in_der_Feuererhaltung
register_type: read
address: 24
unit_of_measurement: "h"
value_type: U_WORD
binary_sensor:
- platform: template
name: "${name} Kesselzustand Heizen"
id: ${name}_Kesselzustand_Heizen
lambda: |-
if (id(${name}_Kesselzustand).state == "Heizen") {
return true;
} else {
return false;
}
+62
View File
@@ -0,0 +1,62 @@
sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Puffer 1 Temperatur oben"
id: ${name}_Puffer_1_Temperatur_oben
register_type: read
address: 2000
unit_of_measurement: "°C"
value_type: U_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Puffer 1 Temperatur mitte"
id: ${name}_Puffer_1_Temperatur_mitte
register_type: read
address: 2001
unit_of_measurement: "°C"
value_type: U_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Puffer 1 Temperatur unten"
id: ${name}_Puffer_1_Temperatur_unten
register_type: read
address: 2002
unit_of_measurement: "°C"
value_type: U_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Puffer 1 Ladezustand"
id: ${name}_Puffer_1_Ladezustand
register_type: read
address: 2006
unit_of_measurement: "%"
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Puffer 1 Pufferpumpen Ansteuerung"
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung
register_type: read
address: 2003
unit_of_measurement: "%"
value_type: U_WORD
binary_sensor:
- platform: template
name: "${name} Puffer 1 Pufferpumpen Ansteuerung AN AUS"
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung_AN_AUS
lambda: |-
if (id(${name}_Puffer_1_Pufferpumpen_Ansteuerung).state > 0) {
return true;
} else {
return false;
}
+28
View File
@@ -0,0 +1,28 @@
sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Ruecklauftemperatur an der Zirkulations Leitung"
id: ${name}_Ruecklauftemperatur_an_der_Zirkulations_Leitung
register_type: read
address: 711
unit_of_measurement: "°C"
value_type: U_WORD
filters:
- multiply: 0.5
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Strömungsschalter an der Brauchwasser Leitung"
id: ${name}_Stoemungsschalter_an_der_Brauchwasser_Leitung
register_type: read
address: 600
value_type: U_WORD
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Drehzahl der Zirkulations Pumpe"
id: ${name}_Drehzahl_der_Zirkulations_Pumpe
register_type: read
address: 710
unit_of_measurement: "%"
value_type: U_WORD