- split up esphome yaml file into muliple pieces for better overview (packages)
- switched to ESP32 board (esp8266 reached OOM) - added few new entities - added Graphical Dashboard "Heizkörper"
This commit is contained in:
1 parent
5022eac1d8
commit
8ce8162385
14 files changed
+850
-572
No files matched your search
@@ -0,0 +1,54 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Fuellstand im Pelletsbehaelter"
|
||||
id: ${name}_Fuellstand_im_Pelletsbehaelter
|
||||
register_type: read
|
||||
address: 21
|
||||
unit_of_measurement: "%"
|
||||
accuracy_decimals: 1
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.0048309178743961
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Resetierbarer kg-Zaehler"
|
||||
id: ${name}_Resetierbarer_kg_Zaehler
|
||||
register_type: read
|
||||
address: 81
|
||||
unit_of_measurement: "kg"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Resetierbarer t-Zaehler"
|
||||
id: ${name}_Resetierbarer_t_Zaehler
|
||||
register_type: read
|
||||
address: 82
|
||||
unit_of_measurement: "t"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Pelletverbrauch Gesamt"
|
||||
id: ${name}_Pelletverbrauch_Gesamt
|
||||
register_type: read
|
||||
address: 83
|
||||
unit_of_measurement: "t"
|
||||
accuracy_decimals: 1
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Pelletlager Restbestand"
|
||||
id: ${name}_Pelletlager_Restbestand
|
||||
register_type: holding
|
||||
address: 319
|
||||
unit_of_measurement: "t"
|
||||
accuracy_decimals: 1
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
@@ -0,0 +1,43 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Boiler 1 Temperatur oben"
|
||||
id: ${name}_Boiler_1_Temperatur_oben
|
||||
register_type: read
|
||||
address: 1630
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Boiler 1 Pumpe Ansteuerung"
|
||||
id: ${name}_Boiler_1_Pumpe_Ansteuerung
|
||||
register_type: read
|
||||
address: 1632
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||
|
||||
number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Boiler 1 Gewünschte Boilertemperatur"
|
||||
id: ${name}_Boiler_1_Gewuenschte_Boilertemperatur
|
||||
address: 1631
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 100
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Boiler 1 Nachladen, wenn Boilertemperatur unter"
|
||||
id: ${name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
|
||||
address: 1632
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 1
|
||||
max_value: 90
|
||||
@@ -0,0 +1,134 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} HK1 - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1030 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} HK1 - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1031 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Aussentemperatur"
|
||||
id: ${name}_Aussentemperatur
|
||||
register_type: read
|
||||
address: 1000
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} HK1 - Pumpe AN AUS"
|
||||
id: ${name}_HK1_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
#address: 999 # Heizkreispumpe 0
|
||||
address: 1029 # Heizkreispumpe 1 - wrong ?
|
||||
|
||||
number:
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} HK1 - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1032
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 110
|
||||
|
||||
# not correct yet ?
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} HK1 - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1031
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 110
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} HK1 - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1039
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 10
|
||||
max_value: 30
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} HK1 - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1033
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 0
|
||||
max_value: 70
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} HK1 - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb
|
||||
einschaltet"
|
||||
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1036
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: -20
|
||||
max_value: 50
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} HK1 - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb
|
||||
einschaltet"
|
||||
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1037
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: -20
|
||||
max_value: 50
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} HK1 - Frostschutztemperatur"
|
||||
id: ${name}_HK1_Frostschutztemperatur
|
||||
address: 1038
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: -10
|
||||
max_value: 20
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} HK1 - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1047
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
min_value: 60
|
||||
max_value: 120
|
||||
@@ -0,0 +1,135 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Kesseltemperatur"
|
||||
id: ${name}_Kesseltemperatur
|
||||
register_type: read
|
||||
address: 0
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Abgastemperatur"
|
||||
id: ${name}_Abgastemperatur
|
||||
register_type: read
|
||||
address: 1
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Verbleibende Heizstunden bis zur Asche entleeren Warnung"
|
||||
id: ${name}_Verbleibende_Heizstunden_bis_zur_Asche_entleeren_Warnung
|
||||
register_type: read
|
||||
address: 86
|
||||
unit_of_measurement: "h"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Saugzug - Ansteuerung"
|
||||
id: ${name}_Saugzug_Ansteuerung
|
||||
register_type: read
|
||||
address: 12
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Saugzugdrehzahl"
|
||||
id: ${name}_Saugzugdrehzahl
|
||||
register_type: read
|
||||
address: 6
|
||||
unit_of_measurement: "rpm"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Sauerstoffregler"
|
||||
id: ${name}_Sauerstoffregler
|
||||
register_type: read
|
||||
address: 16
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Restsauerstoffgehalt"
|
||||
id: ${name}_Restsauerstoffgehalt
|
||||
register_type: read
|
||||
address: 3
|
||||
unit_of_measurement: "%"
|
||||
accuracy_decimals: 1
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Rücklauffühler"
|
||||
id: ${name}_Ruecklauffuehler
|
||||
register_type: read
|
||||
address: 9
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Primärluft"
|
||||
id: ${name}_Primaerluft
|
||||
register_type: read
|
||||
address: 11
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Sekundärluft"
|
||||
id: ${name}_Sekundaerluft
|
||||
register_type: read
|
||||
address: 13
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Betriebsstunden"
|
||||
id: ${name}_Betriebsstunden
|
||||
register_type: read
|
||||
address: 20
|
||||
unit_of_measurement: "h"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Stunden seit letzter Wartung"
|
||||
id: ${name}_Stunden_seit_letzter_Wartung
|
||||
register_type: read
|
||||
address: 55
|
||||
unit_of_measurement: "h"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Betriebsstunden in der Feuererhaltung"
|
||||
id: ${name}_Betriebsstunden_in_der_Feuererhaltung
|
||||
register_type: read
|
||||
address: 24
|
||||
unit_of_measurement: "h"
|
||||
value_type: U_WORD
|
||||
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${name} Kesselzustand Heizen"
|
||||
id: ${name}_Kesselzustand_Heizen
|
||||
lambda: |-
|
||||
if (id(${name}_Kesselzustand).state == "Heizen") {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
}
|
||||
@@ -0,0 +1,62 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Puffer 1 Temperatur oben"
|
||||
id: ${name}_Puffer_1_Temperatur_oben
|
||||
register_type: read
|
||||
address: 2000
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Puffer 1 Temperatur mitte"
|
||||
id: ${name}_Puffer_1_Temperatur_mitte
|
||||
register_type: read
|
||||
address: 2001
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Puffer 1 Temperatur unten"
|
||||
id: ${name}_Puffer_1_Temperatur_unten
|
||||
register_type: read
|
||||
address: 2002
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Puffer 1 Ladezustand"
|
||||
id: ${name}_Puffer_1_Ladezustand
|
||||
register_type: read
|
||||
address: 2006
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Puffer 1 Pufferpumpen Ansteuerung"
|
||||
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung
|
||||
register_type: read
|
||||
address: 2003
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${name} Puffer 1 Pufferpumpen Ansteuerung AN AUS"
|
||||
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${name}_Puffer_1_Pufferpumpen_Ansteuerung).state > 0) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
}
|
||||
@@ -0,0 +1,28 @@
|
||||
sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Ruecklauftemperatur an der Zirkulations Leitung"
|
||||
id: ${name}_Ruecklauftemperatur_an_der_Zirkulations_Leitung
|
||||
register_type: read
|
||||
address: 711
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Strömungsschalter an der Brauchwasser Leitung"
|
||||
id: ${name}_Stoemungsschalter_an_der_Brauchwasser_Leitung
|
||||
register_type: read
|
||||
address: 600
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Drehzahl der Zirkulations Pumpe"
|
||||
id: ${name}_Drehzahl_der_Zirkulations_Pumpe
|
||||
register_type: read
|
||||
address: 710
|
||||
unit_of_measurement: "%"
|
||||
value_type: U_WORD
|
||||