Update wemos-d1-froeling.yaml
This commit is contained in:
@@ -114,6 +114,38 @@ sensor:
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name}-Rücklauffühler"
|
||||
id: ${name}_Ruecklauffuehler
|
||||
register_type: read
|
||||
address: 9
|
||||
unit_of_measurement: "°C"
|
||||
accuracy_decimals: 1
|
||||
value_type: U_WORD
|
||||
filters:
|
||||
- multiply: 0.5
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name}-Primärluft"
|
||||
id: ${name}_Primaerluft
|
||||
register_type: read
|
||||
address: 11
|
||||
unit_of_measurement: "%"
|
||||
accuracy_decimals: 1
|
||||
value_type: U_WORD
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name}-Sekundärluft"
|
||||
id: ${name}_Sekundaerluft
|
||||
register_type: read
|
||||
address: 13
|
||||
unit_of_measurement: "%"
|
||||
accuracy_decimals: 1
|
||||
value_type: U_WORD
|
||||
|
||||
##### Heizkörper HK1 #####
|
||||
# - platform: modbus_controller
|
||||
# modbus_controller_id: ${modbus_controller_id}
|
||||
@@ -314,6 +346,19 @@ number:
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 20
|
||||
max_value: 120
|
||||
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name}-Kessel-Solltemperatur"
|
||||
id: ${name}_Kessel_Solltemperatur
|
||||
address: 0
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
multiply: 2
|
||||
min_value: 70
|
||||
max_value: 90
|
||||
|
||||
text_sensor:
|
||||
- platform: modbus_controller
|
||||
|
||||
Reference in New Issue