Change id
This commit is contained in:
@@ -2,7 +2,7 @@ text_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Anlagenzustand"
|
||||
id: ${name}_Anlagenzustand
|
||||
id: ${lower_name}_Anlagenzustand
|
||||
register_type: read
|
||||
address: 4000
|
||||
raw_encode: HEXBYTES
|
||||
|
||||
@@ -2,7 +2,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Fuellstand im Pelletsbehaelter"
|
||||
id: ${name}_Fuellstand_im_Pelletsbehaelter
|
||||
id: ${lower_name}_Fuellstand_im_Pelletsbehaelter
|
||||
register_type: read
|
||||
address: 21
|
||||
unit_of_measurement: "%"
|
||||
@@ -14,7 +14,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Resetierbarer kg-Zaehler"
|
||||
id: ${name}_Resetierbarer_kg_Zaehler
|
||||
id: ${lower_name}_Resetierbarer_kg_Zaehler
|
||||
register_type: read
|
||||
address: 81
|
||||
unit_of_measurement: "kg"
|
||||
@@ -23,7 +23,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Resetierbarer t-Zaehler"
|
||||
id: ${name}_Resetierbarer_t_Zaehler
|
||||
id: ${lower_name}_Resetierbarer_t_Zaehler
|
||||
register_type: read
|
||||
address: 82
|
||||
unit_of_measurement: "t"
|
||||
@@ -32,7 +32,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Pelletverbrauch Gesamt"
|
||||
id: ${name}_Pelletverbrauch_Gesamt
|
||||
id: ${lower_name}_Pelletverbrauch_Gesamt
|
||||
register_type: read
|
||||
address: 83
|
||||
unit_of_measurement: "t"
|
||||
@@ -44,7 +44,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Pelletlager Restbestand"
|
||||
id: ${name}_Pelletlager_Restbestand
|
||||
id: ${lower_name}_Pelletlager_Restbestand
|
||||
register_type: holding
|
||||
address: 319
|
||||
unit_of_measurement: "t"
|
||||
|
||||
@@ -2,7 +2,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${boiler1_name} Temperatur oben"
|
||||
id: ${name}_Boiler_1_Temperatur_oben
|
||||
id: ${lower_name}_Boiler_1_Temperatur_oben
|
||||
register_type: read
|
||||
address: 1630
|
||||
unit_of_measurement: "°C"
|
||||
@@ -13,7 +13,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${boiler1_name} Pumpe Ansteuerung"
|
||||
id: ${name}_Boiler_1_Pumpe_Ansteuerung
|
||||
id: ${lower_name}_Boiler_1_Pumpe_Ansteuerung
|
||||
register_type: read
|
||||
address: 1632
|
||||
unit_of_measurement: "%"
|
||||
@@ -23,7 +23,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${boiler1_name} Gewünschte Boilertemperatur"
|
||||
id: ${name}_Boiler_1_Gewuenschte_Boilertemperatur
|
||||
id: ${lower_name}_Boiler_1_Gewuenschte_Boilertemperatur
|
||||
address: 1631
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -34,7 +34,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${boiler1_name} Nachladen, wenn Boilertemperatur unter"
|
||||
id: ${name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
|
||||
id: ${lower_name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
|
||||
address: 1632
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -45,9 +45,9 @@ number:
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${boiler1_name} Pumpe Ansteuerung AN AUS"
|
||||
id: ${name}_Boiler_1_Pumpe_Ansteuerung_AN_AUS
|
||||
id: ${lower_name}_Boiler_1_Pumpe_Ansteuerung_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${name}_Boiler_1_Pumpe_Ansteuerung).state > 0) {
|
||||
if (id(${lower_name}_Boiler_1_Pumpe_Ansteuerung).state > 0) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
|
||||
10
fehler.yaml
10
fehler.yaml
@@ -4,7 +4,7 @@ text_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Fehler 1"
|
||||
id: ${name}_Fehler_1
|
||||
id: ${lower_name}_Fehler_1
|
||||
register_type: read
|
||||
address: 3000
|
||||
raw_encode: HEXBYTES
|
||||
@@ -448,7 +448,7 @@ text_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Fehler 2"
|
||||
id: ${name}_Fehler_2
|
||||
id: ${lower_name}_Fehler_2
|
||||
register_type: read
|
||||
address: 3001
|
||||
raw_encode: HEXBYTES
|
||||
@@ -892,7 +892,7 @@ text_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Fehler 3"
|
||||
id: ${name}_Fehler_3
|
||||
id: ${lower_name}_Fehler_3
|
||||
register_type: read
|
||||
address: 3002
|
||||
raw_encode: HEXBYTES
|
||||
@@ -1336,7 +1336,7 @@ text_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Fehler 4"
|
||||
id: ${name}_Fehler_4
|
||||
id: ${lower_name}_Fehler_4
|
||||
register_type: read
|
||||
address: 3003
|
||||
raw_encode: HEXBYTES
|
||||
@@ -1780,7 +1780,7 @@ text_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Fehler 5"
|
||||
id: ${name}_Fehler_5
|
||||
id: ${lower_name}_Fehler_5
|
||||
register_type: read
|
||||
address: 3004
|
||||
raw_encode: HEXBYTES
|
||||
|
||||
@@ -2,7 +2,7 @@ select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Betriebsart"
|
||||
id: ${name}_HK1_Betriebsart
|
||||
id: ${lower_name}_HK1_Betriebsart
|
||||
address: 8046
|
||||
value_type: U_WORD
|
||||
optionsmap:
|
||||
@@ -17,7 +17,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Isttemperatur
|
||||
id: ${lower_name}_HK1_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1030 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -28,7 +28,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Solltemperatur
|
||||
id: ${lower_name}_HK1_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1031 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -39,7 +39,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Raumtemperatur"
|
||||
id: ${name}_HK1_Raumtemperatur
|
||||
id: ${lower_name}_HK1_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1032 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -51,7 +51,7 @@ binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK1_Pumpe_AN_AUS
|
||||
id: ${lower_name}_HK1_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
address: 1029
|
||||
|
||||
@@ -60,7 +60,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
id: ${lower_name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1032
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -72,7 +72,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
id: ${lower_name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1031
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -83,7 +83,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
id: ${lower_name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1039
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -94,7 +94,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
id: ${lower_name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1033
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -105,7 +105,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
address: 1035
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -116,7 +116,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
address: 1040
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -127,7 +127,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1036
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -138,7 +138,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1037
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -149,7 +149,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK1_Frostschutztemperatur
|
||||
id: ${lower_name}_HK1_Frostschutztemperatur
|
||||
address: 1038
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -160,7 +160,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk1_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
id: ${lower_name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1047
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
|
||||
@@ -2,7 +2,7 @@ select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Betriebsart"
|
||||
id: ${name}_HK2_Betriebsart
|
||||
id: ${lower_name}_HK2_Betriebsart
|
||||
address: 8047
|
||||
value_type: U_WORD
|
||||
optionsmap:
|
||||
@@ -17,7 +17,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Isttemperatur
|
||||
id: ${lower_name}_HK2_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1060 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -28,7 +28,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Solltemperatur
|
||||
id: ${lower_name}_HK2_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1061 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -39,7 +39,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Raumtemperatur"
|
||||
id: ${name}_HK2_Raumtemperatur
|
||||
id: ${lower_name}_HK2_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1062 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -51,7 +51,7 @@ binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK2_Pumpe_AN_AUS
|
||||
id: ${lower_name}_HK2_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
address: 1059
|
||||
|
||||
@@ -60,7 +60,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
id: ${lower_name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1061
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -72,7 +72,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
id: ${lower_name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1062
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -83,7 +83,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
id: ${lower_name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1063
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -94,7 +94,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
id: ${lower_name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1069
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -105,7 +105,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
address: 1065
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -116,7 +116,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
address: 1070
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -127,7 +127,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1066
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -138,7 +138,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1067
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -149,7 +149,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK2_Frostschutztemperatur
|
||||
id: ${lower_name}_HK2_Frostschutztemperatur
|
||||
address: 1068
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -160,7 +160,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk2_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
id: ${lower_name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1078
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
|
||||
@@ -2,7 +2,7 @@ select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Betriebsart"
|
||||
id: ${name}_HK3_Betriebsart
|
||||
id: ${lower_name}_HK3_Betriebsart
|
||||
address: 8048
|
||||
value_type: U_WORD
|
||||
optionsmap:
|
||||
@@ -17,7 +17,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK3_Vorlauf_Isttemperatur
|
||||
id: ${lower_name}_HK3_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1090 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -28,7 +28,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK3_Vorlauf_Solltemperatur
|
||||
id: ${lower_name}_HK3_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1091 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -39,7 +39,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Raumtemperatur"
|
||||
id: ${name}_HK3_Raumtemperatur
|
||||
id: ${lower_name}_HK3_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1092 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -51,7 +51,7 @@ binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK3_Pumpe_AN_AUS
|
||||
id: ${lower_name}_HK3_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
address: 1090
|
||||
|
||||
@@ -60,7 +60,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK3_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
id: ${lower_name}_HK3_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1091
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -72,7 +72,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK3_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
id: ${lower_name}_HK3_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1092
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -83,7 +83,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK3_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
id: ${lower_name}_HK3_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1093
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -94,7 +94,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK3_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
id: ${lower_name}_HK3_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1099
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -105,7 +105,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
id: ${lower_name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
address: 1095
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -116,7 +116,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
id: ${lower_name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
address: 1100
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -127,7 +127,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
id: ${lower_name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1096
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -138,7 +138,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
id: ${lower_name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1097
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -149,7 +149,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK3_Frostschutztemperatur
|
||||
id: ${lower_name}_HK3_Frostschutztemperatur
|
||||
address: 1098
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -160,7 +160,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk3_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK3_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
id: ${lower_name}_HK3_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1105
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
|
||||
@@ -2,7 +2,7 @@ select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Betriebsart"
|
||||
id: ${name}_HK4_Betriebsart
|
||||
id: ${lower_name}_HK4_Betriebsart
|
||||
address: 8049
|
||||
value_type: U_WORD
|
||||
optionsmap:
|
||||
@@ -17,7 +17,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK4_Vorlauf_Isttemperatur
|
||||
id: ${lower_name}_HK4_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1120 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -28,7 +28,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK4_Vorlauf_Solltemperatur
|
||||
id: ${lower_name}_HK4_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1121 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -39,7 +39,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Raumtemperatur"
|
||||
id: ${name}_HK4_Raumtemperatur
|
||||
id: ${lower_name}_HK4_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1122 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -51,7 +51,7 @@ binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK4_Pumpe_AN_AUS
|
||||
id: ${lower_name}_HK4_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
address: 1120
|
||||
|
||||
@@ -60,7 +60,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK4_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
id: ${lower_name}_HK4_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1121
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -72,7 +72,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK4_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
id: ${lower_name}_HK4_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1122
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -83,7 +83,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK4_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
id: ${lower_name}_HK4_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1123
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -94,7 +94,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK4_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
id: ${lower_name}_HK4_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1129
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -105,7 +105,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
address: 1125
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -116,7 +116,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
address: 1130
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -127,7 +127,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1126
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -138,7 +138,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1127
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -149,7 +149,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK4_Frostschutztemperatur
|
||||
id: ${lower_name}_HK4_Frostschutztemperatur
|
||||
address: 1128
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -160,7 +160,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk4_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK4_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
id: ${lower_name}_HK4_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1135
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
|
||||
@@ -2,7 +2,7 @@ select:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Betriebsart"
|
||||
id: ${name}_HK5_Betriebsart
|
||||
id: ${lower_name}_HK5_Betriebsart
|
||||
address: 8050
|
||||
value_type: U_WORD
|
||||
optionsmap:
|
||||
@@ -17,7 +17,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Vorlauf-Isttemperatur"
|
||||
id: ${name}_HK5_Vorlauf_Isttemperatur
|
||||
id: ${lower_name}_HK5_Vorlauf_Isttemperatur
|
||||
register_type: read
|
||||
address: 1150 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -28,7 +28,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Vorlauf-Solltemperatur"
|
||||
id: ${name}_HK5_Vorlauf_Solltemperatur
|
||||
id: ${lower_name}_HK5_Vorlauf_Solltemperatur
|
||||
register_type: read
|
||||
address: 1151 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -39,7 +39,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Raumtemperatur"
|
||||
id: ${name}_HK5_Raumtemperatur
|
||||
id: ${lower_name}_HK5_Raumtemperatur
|
||||
register_type: read
|
||||
address: 1152 #Wrong ?
|
||||
unit_of_measurement: "°C"
|
||||
@@ -51,7 +51,7 @@ binary_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Pumpe AN AUS"
|
||||
id: ${name}_HK5_Pumpe_AN_AUS
|
||||
id: ${lower_name}_HK5_Pumpe_AN_AUS
|
||||
register_type: coil
|
||||
address: 1150
|
||||
|
||||
@@ -60,7 +60,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
|
||||
id: ${name}_HK5_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
id: ${lower_name}_HK5_Vorlauf_Temperatur_10C_Aussentemperatur
|
||||
address: 1151
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -72,7 +72,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
|
||||
id: ${name}_HK5_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
id: ${lower_name}_HK5_Vorlauf_Temperatur_minus_10C_Aussentemperatur
|
||||
address: 1152
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -83,7 +83,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
|
||||
id: ${name}_HK5_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
id: ${lower_name}_HK5_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
|
||||
address: 1153
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -94,7 +94,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
|
||||
id: ${name}_HK5_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
id: ${lower_name}_HK5_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
|
||||
address: 1159
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -105,7 +105,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
|
||||
id: ${name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
id: ${lower_name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
|
||||
address: 1155
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -116,7 +116,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
|
||||
id: ${name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
id: ${lower_name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
|
||||
address: 1160
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -127,7 +127,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
|
||||
id: ${name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
id: ${lower_name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
|
||||
address: 1156
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -138,7 +138,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
|
||||
id: ${name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
id: ${lower_name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
|
||||
address: 1157
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -149,7 +149,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Frostschutztemperatur"
|
||||
id: ${name}_HK5_Frostschutztemperatur
|
||||
id: ${lower_name}_HK5_Frostschutztemperatur
|
||||
address: 1158
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
@@ -160,7 +160,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${hk5_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
|
||||
id: ${name}_HK5_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
id: ${lower_name}_HK5_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
|
||||
address: 1165
|
||||
unit_of_measurement: "°C"
|
||||
value_type: S_WORD
|
||||
|
||||
42
kessel.yaml
42
kessel.yaml
@@ -2,7 +2,7 @@ text_sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Kesselzustand"
|
||||
id: ${name}_Kesselzustand
|
||||
id: ${lower_name}_Kesselzustand
|
||||
register_type: read
|
||||
address: 4001
|
||||
raw_encode: HEXBYTES
|
||||
@@ -100,7 +100,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Kesseltemperatur"
|
||||
id: ${name}_Kesseltemperatur
|
||||
id: ${lower_name}_Kesseltemperatur
|
||||
register_type: read
|
||||
address: 0
|
||||
unit_of_measurement: "°C"
|
||||
@@ -111,7 +111,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Abgastemperatur"
|
||||
id: ${name}_Abgastemperatur
|
||||
id: ${lower_name}_Abgastemperatur
|
||||
register_type: read
|
||||
address: 1
|
||||
unit_of_measurement: "°C"
|
||||
@@ -120,7 +120,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Saugzug - Ansteuerung"
|
||||
id: ${name}_Saugzug_Ansteuerung
|
||||
id: ${lower_name}_Saugzug_Ansteuerung
|
||||
register_type: read
|
||||
address: 13
|
||||
unit_of_measurement: "%"
|
||||
@@ -129,7 +129,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Saugzugdrehzahl"
|
||||
id: ${name}_Saugzugdrehzahl
|
||||
id: ${lower_name}_Saugzugdrehzahl
|
||||
register_type: read
|
||||
address: 6
|
||||
unit_of_measurement: "rpm"
|
||||
@@ -138,7 +138,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Sauerstoffregler"
|
||||
id: ${name}_Sauerstoffregler
|
||||
id: ${lower_name}_Sauerstoffregler
|
||||
register_type: read
|
||||
address: 16
|
||||
unit_of_measurement: "%"
|
||||
@@ -147,7 +147,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Restsauerstoffgehalt"
|
||||
id: ${name}_Restsauerstoffgehalt
|
||||
id: ${lower_name}_Restsauerstoffgehalt
|
||||
register_type: read
|
||||
address: 3
|
||||
unit_of_measurement: "%"
|
||||
@@ -159,7 +159,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Rücklauffühler"
|
||||
id: ${name}_Ruecklauffuehler
|
||||
id: ${lower_name}_Ruecklauffuehler
|
||||
register_type: read
|
||||
address: 9
|
||||
unit_of_measurement: "°C"
|
||||
@@ -170,7 +170,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Primärluft"
|
||||
id: ${name}_Primaerluft
|
||||
id: ${lower_name}_Primaerluft
|
||||
register_type: read
|
||||
address: 11
|
||||
unit_of_measurement: "%"
|
||||
@@ -179,7 +179,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Sekundärluft"
|
||||
id: ${name}_Sekundaerluft
|
||||
id: ${lower_name}_Sekundaerluft
|
||||
register_type: read
|
||||
address: 12
|
||||
unit_of_measurement: "%"
|
||||
@@ -188,7 +188,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Kesselstellgröße"
|
||||
id: ${name}_Kesselstellgroesse
|
||||
id: ${lower_name}_Kesselstellgroesse
|
||||
register_type: read
|
||||
address: 14
|
||||
unit_of_measurement: "%"
|
||||
@@ -197,7 +197,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Betriebsstunden"
|
||||
id: ${name}_Betriebsstunden
|
||||
id: ${lower_name}_Betriebsstunden
|
||||
register_type: read
|
||||
address: 20
|
||||
unit_of_measurement: "h"
|
||||
@@ -206,7 +206,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Anzahl der Brennerstarts"
|
||||
id: ${name}_Anzahl_der_Brennerstarts
|
||||
id: ${lower_name}_Anzahl_der_Brennerstarts
|
||||
register_type: read
|
||||
address: 22
|
||||
value_type: U_WORD
|
||||
@@ -214,7 +214,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Betriebsstunden in der Feuererhaltung"
|
||||
id: ${name}_Betriebsstunden_in_der_Feuererhaltung
|
||||
id: ${lower_name}_Betriebsstunden_in_der_Feuererhaltung
|
||||
register_type: read
|
||||
address: 24
|
||||
unit_of_measurement: "h"
|
||||
@@ -223,7 +223,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Errechnete Kesselsolltemperatur"
|
||||
id: ${name}_Errechnete_Kesselsolltemperatur
|
||||
id: ${lower_name}_Errechnete_Kesselsolltemperatur
|
||||
register_type: read
|
||||
address: 27
|
||||
unit_of_measurement: "°C"
|
||||
@@ -234,7 +234,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Stunden seit letzter Wartung"
|
||||
id: ${name}_Stunden_seit_letzter_Wartung
|
||||
id: ${lower_name}_Stunden_seit_letzter_Wartung
|
||||
register_type: read
|
||||
address: 55
|
||||
unit_of_measurement: "h"
|
||||
@@ -243,7 +243,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Verbleibende Heizstunden bis zur Asche entleeren Warnung"
|
||||
id: ${name}_Verbleibende_Heizstunden_bis_zur_Asche_entleeren_Warnung
|
||||
id: ${lower_name}_Verbleibende_Heizstunden_bis_zur_Asche_entleeren_Warnung
|
||||
register_type: read
|
||||
address: 86
|
||||
unit_of_measurement: "h"
|
||||
@@ -252,7 +252,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Aussentemperatur"
|
||||
id: ${name}_Aussentemperatur
|
||||
id: ${lower_name}_Aussentemperatur
|
||||
register_type: read
|
||||
address: 1000
|
||||
unit_of_measurement: "°C"
|
||||
@@ -263,9 +263,9 @@ sensor:
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${name} Kesselzustand Heizen"
|
||||
id: ${name}_Kesselzustand_Heizen
|
||||
id: ${lower_name}_Kesselzustand_Heizen
|
||||
lambda: |-
|
||||
if (id(${name}_Kesselzustand).state == "Heizen") {
|
||||
if (id(${lower_name}_Kesselzustand).state == "Heizen") {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
@@ -275,7 +275,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Kessel-Solltemperatur"
|
||||
id: ${name}_Kessel_Solltemperatur
|
||||
id: ${lower_name}_Kessel_Solltemperatur
|
||||
address: 0
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
|
||||
@@ -2,7 +2,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Drehzahl Netzpumpe"
|
||||
id: ${name}_Drehzahl_Netzpumpe
|
||||
id: ${lower_name}_Drehzahl_Netzpumpe
|
||||
register_type: read
|
||||
address: 700
|
||||
unit_of_measurement: "%"
|
||||
@@ -11,7 +11,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Netzrücklauf Temperatur"
|
||||
id: ${name}_Netzruecklauf_Temperatur
|
||||
id: ${lower_name}_Netzruecklauf_Temperatur
|
||||
register_type: read
|
||||
address: 701
|
||||
unit_of_measurement: "°C"
|
||||
@@ -22,9 +22,9 @@ sensor:
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${name} Netzpumpe AN AUS"
|
||||
id: ${name}_Netzpumpe_AN_AUS
|
||||
id: ${lower_name}_Netzpumpe_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${name}_Drehzahl_Netzpumpe).state > 0) {
|
||||
if (id(${lower_name}_Drehzahl_Netzpumpe).state > 0) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
|
||||
@@ -2,7 +2,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${puffer1_name} Temperatur oben"
|
||||
id: ${name}_Puffer_1_Temperatur_oben
|
||||
id: ${lower_name}_Puffer_1_Temperatur_oben
|
||||
register_type: read
|
||||
address: 2000
|
||||
unit_of_measurement: "°C"
|
||||
@@ -13,7 +13,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${puffer1_name} Temperatur mitte"
|
||||
id: ${name}_Puffer_1_Temperatur_mitte
|
||||
id: ${lower_name}_Puffer_1_Temperatur_mitte
|
||||
register_type: read
|
||||
address: 2001
|
||||
unit_of_measurement: "°C"
|
||||
@@ -24,7 +24,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${puffer1_name} Temperatur unten"
|
||||
id: ${name}_Puffer_1_Temperatur_unten
|
||||
id: ${lower_name}_Puffer_1_Temperatur_unten
|
||||
register_type: read
|
||||
address: 2002
|
||||
unit_of_measurement: "°C"
|
||||
@@ -35,7 +35,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${puffer1_name} Ladezustand"
|
||||
id: ${name}_Puffer_1_Ladezustand
|
||||
id: ${lower_name}_Puffer_1_Ladezustand
|
||||
register_type: read
|
||||
address: 2006
|
||||
unit_of_measurement: "%"
|
||||
@@ -44,7 +44,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${puffer1_name} Pufferpumpen Ansteuerung"
|
||||
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung
|
||||
id: ${lower_name}_Puffer_1_Pufferpumpen_Ansteuerung
|
||||
register_type: read
|
||||
address: 2003
|
||||
unit_of_measurement: "%"
|
||||
@@ -53,9 +53,9 @@ sensor:
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${puffer1_name} Pufferpumpen Ansteuerung AN AUS"
|
||||
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung_AN_AUS
|
||||
id: ${lower_name}_Puffer_1_Pufferpumpen_Ansteuerung_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${name}_Puffer_1_Pufferpumpen_Ansteuerung).state > 0) {
|
||||
if (id(${lower_name}_Puffer_1_Pufferpumpen_Ansteuerung).state > 0) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
|
||||
@@ -2,7 +2,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Ruecklauftemperatur an der Zirkulations Leitung"
|
||||
id: ${name}_Ruecklauftemperatur_an_der_Zirkulations_Leitung
|
||||
id: ${lower_name}_Ruecklauftemperatur_an_der_Zirkulations_Leitung
|
||||
register_type: read
|
||||
address: 711
|
||||
unit_of_measurement: "°C"
|
||||
@@ -13,7 +13,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Strömungsschalter an der Brauchwasser Leitung"
|
||||
id: ${name}_Stoemungsschalter_an_der_Brauchwasser_Leitung
|
||||
id: ${lower_name}_Stoemungsschalter_an_der_Brauchwasser_Leitung
|
||||
register_type: read
|
||||
address: 600
|
||||
value_type: U_WORD
|
||||
@@ -21,7 +21,7 @@ sensor:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Drehzahl der Zirkulations Pumpe"
|
||||
id: ${name}_Drehzahl_der_Zirkulations_Pumpe
|
||||
id: ${lower_name}_Drehzahl_der_Zirkulations_Pumpe
|
||||
register_type: read
|
||||
address: 710
|
||||
unit_of_measurement: "%"
|
||||
@@ -30,9 +30,9 @@ sensor:
|
||||
binary_sensor:
|
||||
- platform: template
|
||||
name: "${name} Zirkulationspumpe AN AUS"
|
||||
id: ${name}_Zirkulations_Pumpe_AN_AUS
|
||||
id: ${lower_name}_Zirkulations_Pumpe_AN_AUS
|
||||
lambda: |-
|
||||
if (id(${name}_Drehzahl_der_Zirkulations_Pumpe).state > 0) {
|
||||
if (id(${lower_name}_Drehzahl_der_Zirkulations_Pumpe).state > 0) {
|
||||
return true;
|
||||
} else {
|
||||
return false;
|
||||
@@ -42,7 +42,7 @@ number:
|
||||
- platform: modbus_controller
|
||||
modbus_controller_id: ${modbus_controller_id}
|
||||
name: "${name} Bei welcher RL Temperatur an der Zirkulationsleitung soll die Pumpe ausschalten"
|
||||
id: ${name}_Bei_welcher_RL_Temperatur_an_der_Zirkulationsleitung_soll_die_Pumpe_ausschalten
|
||||
id: ${lower_name}_Bei_welcher_RL_Temperatur_an_der_Zirkulationsleitung_soll_die_Pumpe_ausschalten
|
||||
address: 600
|
||||
unit_of_measurement: "°C"
|
||||
value_type: U_WORD
|
||||
|
||||