@@ -2,7 +2,7 @@ text_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Anlagenzustand"
id: ${name}_Anlagenzustand
id: ${lower_name}_Anlagenzustand
register_type: read
address: 4000
raw_encode: HEXBYTES

View File

@@ -2,7 +2,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Fuellstand im Pelletsbehaelter"
id: ${name}_Fuellstand_im_Pelletsbehaelter
id: ${lower_name}_Fuellstand_im_Pelletsbehaelter
register_type: read
address: 21
unit_of_measurement: "%"
@@ -14,7 +14,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Resetierbarer kg-Zaehler"
id: ${name}_Resetierbarer_kg_Zaehler
id: ${lower_name}_Resetierbarer_kg_Zaehler
register_type: read
address: 81
unit_of_measurement: "kg"
@@ -23,7 +23,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Resetierbarer t-Zaehler"
id: ${name}_Resetierbarer_t_Zaehler
id: ${lower_name}_Resetierbarer_t_Zaehler
register_type: read
address: 82
unit_of_measurement: "t"
@@ -32,7 +32,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Pelletverbrauch Gesamt"
id: ${name}_Pelletverbrauch_Gesamt
id: ${lower_name}_Pelletverbrauch_Gesamt
register_type: read
address: 83
unit_of_measurement: "t"
@@ -44,7 +44,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Pelletlager Restbestand"
id: ${name}_Pelletlager_Restbestand
id: ${lower_name}_Pelletlager_Restbestand
register_type: holding
address: 319
unit_of_measurement: "t"

View File

@@ -2,7 +2,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${boiler1_name} Temperatur oben"
id: ${name}_Boiler_1_Temperatur_oben
id: ${lower_name}_Boiler_1_Temperatur_oben
register_type: read
address: 1630
unit_of_measurement: "°C"
@@ -13,7 +13,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${boiler1_name} Pumpe Ansteuerung"
id: ${name}_Boiler_1_Pumpe_Ansteuerung
id: ${lower_name}_Boiler_1_Pumpe_Ansteuerung
register_type: read
address: 1632
unit_of_measurement: "%"
@@ -23,7 +23,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${boiler1_name} Gewünschte Boilertemperatur"
id: ${name}_Boiler_1_Gewuenschte_Boilertemperatur
id: ${lower_name}_Boiler_1_Gewuenschte_Boilertemperatur
address: 1631
unit_of_measurement: "°C"
value_type: S_WORD
@@ -34,7 +34,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${boiler1_name} Nachladen, wenn Boilertemperatur unter"
id: ${name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
id: ${lower_name}_Boiler_1_Nachladen_wenn_Boilertemperatur_unter
address: 1632
unit_of_measurement: "°C"
value_type: S_WORD
@@ -45,9 +45,9 @@ number:
binary_sensor:
- platform: template
name: "${boiler1_name} Pumpe Ansteuerung AN AUS"
id: ${name}_Boiler_1_Pumpe_Ansteuerung_AN_AUS
id: ${lower_name}_Boiler_1_Pumpe_Ansteuerung_AN_AUS
lambda: |-
if (id(${name}_Boiler_1_Pumpe_Ansteuerung).state > 0) {
if (id(${lower_name}_Boiler_1_Pumpe_Ansteuerung).state > 0) {
return true;
} else {
return false;

View File

@@ -4,7 +4,7 @@ text_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Fehler 1"
id: ${name}_Fehler_1
id: ${lower_name}_Fehler_1
register_type: read
address: 3000
raw_encode: HEXBYTES
@@ -448,7 +448,7 @@ text_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Fehler 2"
id: ${name}_Fehler_2
id: ${lower_name}_Fehler_2
register_type: read
address: 3001
raw_encode: HEXBYTES
@@ -892,7 +892,7 @@ text_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Fehler 3"
id: ${name}_Fehler_3
id: ${lower_name}_Fehler_3
register_type: read
address: 3002
raw_encode: HEXBYTES
@@ -1336,7 +1336,7 @@ text_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Fehler 4"
id: ${name}_Fehler_4
id: ${lower_name}_Fehler_4
register_type: read
address: 3003
raw_encode: HEXBYTES
@@ -1780,7 +1780,7 @@ text_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Fehler 5"
id: ${name}_Fehler_5
id: ${lower_name}_Fehler_5
register_type: read
address: 3004
raw_encode: HEXBYTES

View File

@@ -2,7 +2,7 @@ select:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Betriebsart"
id: ${name}_HK1_Betriebsart
id: ${lower_name}_HK1_Betriebsart
address: 8046
value_type: U_WORD
optionsmap:
@@ -17,7 +17,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Vorlauf-Isttemperatur"
id: ${name}_HK1_Vorlauf_Isttemperatur
id: ${lower_name}_HK1_Vorlauf_Isttemperatur
register_type: read
address: 1030 #Wrong ?
unit_of_measurement: "°C"
@@ -28,7 +28,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Vorlauf-Solltemperatur"
id: ${name}_HK1_Vorlauf_Solltemperatur
id: ${lower_name}_HK1_Vorlauf_Solltemperatur
register_type: read
address: 1031 #Wrong ?
unit_of_measurement: "°C"
@@ -39,7 +39,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Raumtemperatur"
id: ${name}_HK1_Raumtemperatur
id: ${lower_name}_HK1_Raumtemperatur
register_type: read
address: 1032 #Wrong ?
unit_of_measurement: "°C"
@@ -51,7 +51,7 @@ binary_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Pumpe AN AUS"
id: ${name}_HK1_Pumpe_AN_AUS
id: ${lower_name}_HK1_Pumpe_AN_AUS
register_type: coil
address: 1029
@@ -60,7 +60,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
id: ${name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
id: ${lower_name}_HK1_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1032
unit_of_measurement: "°C"
value_type: S_WORD
@@ -72,7 +72,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
id: ${name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
id: ${lower_name}_HK1_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1031
unit_of_measurement: "°C"
value_type: S_WORD
@@ -83,7 +83,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
id: ${name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
id: ${lower_name}_HK1_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1039
unit_of_measurement: "°C"
value_type: S_WORD
@@ -94,7 +94,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
id: ${name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
id: ${lower_name}_HK1_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1033
unit_of_measurement: "°C"
value_type: S_WORD
@@ -105,7 +105,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
id: ${name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1035
unit_of_measurement: "°C"
value_type: S_WORD
@@ -116,7 +116,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
id: ${name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
id: ${lower_name}_HK1_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1040
unit_of_measurement: "°C"
value_type: S_WORD
@@ -127,7 +127,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1036
unit_of_measurement: "°C"
value_type: S_WORD
@@ -138,7 +138,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
id: ${name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
id: ${lower_name}_HK1_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1037
unit_of_measurement: "°C"
value_type: S_WORD
@@ -149,7 +149,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Frostschutztemperatur"
id: ${name}_HK1_Frostschutztemperatur
id: ${lower_name}_HK1_Frostschutztemperatur
address: 1038
unit_of_measurement: "°C"
value_type: S_WORD
@@ -160,7 +160,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk1_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
id: ${name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
id: ${lower_name}_HK1_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1047
unit_of_measurement: "°C"
value_type: S_WORD

View File

@@ -2,7 +2,7 @@ select:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Betriebsart"
id: ${name}_HK2_Betriebsart
id: ${lower_name}_HK2_Betriebsart
address: 8047
value_type: U_WORD
optionsmap:
@@ -17,7 +17,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Vorlauf-Isttemperatur"
id: ${name}_HK2_Vorlauf_Isttemperatur
id: ${lower_name}_HK2_Vorlauf_Isttemperatur
register_type: read
address: 1060 #Wrong ?
unit_of_measurement: "°C"
@@ -28,7 +28,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Vorlauf-Solltemperatur"
id: ${name}_HK2_Vorlauf_Solltemperatur
id: ${lower_name}_HK2_Vorlauf_Solltemperatur
register_type: read
address: 1061 #Wrong ?
unit_of_measurement: "°C"
@@ -39,7 +39,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Raumtemperatur"
id: ${name}_HK2_Raumtemperatur
id: ${lower_name}_HK2_Raumtemperatur
register_type: read
address: 1062 #Wrong ?
unit_of_measurement: "°C"
@@ -51,7 +51,7 @@ binary_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Pumpe AN AUS"
id: ${name}_HK2_Pumpe_AN_AUS
id: ${lower_name}_HK2_Pumpe_AN_AUS
register_type: coil
address: 1059
@@ -60,7 +60,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
id: ${name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur
id: ${lower_name}_HK2_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1061
unit_of_measurement: "°C"
value_type: S_WORD
@@ -72,7 +72,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
id: ${name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur
id: ${lower_name}_HK2_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1062
unit_of_measurement: "°C"
value_type: S_WORD
@@ -83,7 +83,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
id: ${name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
id: ${lower_name}_HK2_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1063
unit_of_measurement: "°C"
value_type: S_WORD
@@ -94,7 +94,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
id: ${name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
id: ${lower_name}_HK2_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1069
unit_of_measurement: "°C"
value_type: S_WORD
@@ -105,7 +105,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
id: ${name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1065
unit_of_measurement: "°C"
value_type: S_WORD
@@ -116,7 +116,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
id: ${name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
id: ${lower_name}_HK2_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1070
unit_of_measurement: "°C"
value_type: S_WORD
@@ -127,7 +127,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1066
unit_of_measurement: "°C"
value_type: S_WORD
@@ -138,7 +138,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
id: ${name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
id: ${lower_name}_HK2_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1067
unit_of_measurement: "°C"
value_type: S_WORD
@@ -149,7 +149,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Frostschutztemperatur"
id: ${name}_HK2_Frostschutztemperatur
id: ${lower_name}_HK2_Frostschutztemperatur
address: 1068
unit_of_measurement: "°C"
value_type: S_WORD
@@ -160,7 +160,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk2_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
id: ${name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
id: ${lower_name}_HK2_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1078
unit_of_measurement: "°C"
value_type: S_WORD

View File

@@ -2,7 +2,7 @@ select:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Betriebsart"
id: ${name}_HK3_Betriebsart
id: ${lower_name}_HK3_Betriebsart
address: 8048
value_type: U_WORD
optionsmap:
@@ -17,7 +17,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Vorlauf-Isttemperatur"
id: ${name}_HK3_Vorlauf_Isttemperatur
id: ${lower_name}_HK3_Vorlauf_Isttemperatur
register_type: read
address: 1090 #Wrong ?
unit_of_measurement: "°C"
@@ -28,7 +28,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Vorlauf-Solltemperatur"
id: ${name}_HK3_Vorlauf_Solltemperatur
id: ${lower_name}_HK3_Vorlauf_Solltemperatur
register_type: read
address: 1091 #Wrong ?
unit_of_measurement: "°C"
@@ -39,7 +39,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Raumtemperatur"
id: ${name}_HK3_Raumtemperatur
id: ${lower_name}_HK3_Raumtemperatur
register_type: read
address: 1092 #Wrong ?
unit_of_measurement: "°C"
@@ -51,7 +51,7 @@ binary_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Pumpe AN AUS"
id: ${name}_HK3_Pumpe_AN_AUS
id: ${lower_name}_HK3_Pumpe_AN_AUS
register_type: coil
address: 1090
@@ -60,7 +60,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
id: ${name}_HK3_Vorlauf_Temperatur_10C_Aussentemperatur
id: ${lower_name}_HK3_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1091
unit_of_measurement: "°C"
value_type: S_WORD
@@ -72,7 +72,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
id: ${name}_HK3_Vorlauf_Temperatur_minus_10C_Aussentemperatur
id: ${lower_name}_HK3_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1092
unit_of_measurement: "°C"
value_type: S_WORD
@@ -83,7 +83,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
id: ${name}_HK3_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
id: ${lower_name}_HK3_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1093
unit_of_measurement: "°C"
value_type: S_WORD
@@ -94,7 +94,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
id: ${name}_HK3_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
id: ${lower_name}_HK3_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1099
unit_of_measurement: "°C"
value_type: S_WORD
@@ -105,7 +105,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
id: ${name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
id: ${lower_name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1095
unit_of_measurement: "°C"
value_type: S_WORD
@@ -116,7 +116,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
id: ${name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
id: ${lower_name}_HK3_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1100
unit_of_measurement: "°C"
value_type: S_WORD
@@ -127,7 +127,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
id: ${name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
id: ${lower_name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1096
unit_of_measurement: "°C"
value_type: S_WORD
@@ -138,7 +138,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
id: ${name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
id: ${lower_name}_HK3_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1097
unit_of_measurement: "°C"
value_type: S_WORD
@@ -149,7 +149,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Frostschutztemperatur"
id: ${name}_HK3_Frostschutztemperatur
id: ${lower_name}_HK3_Frostschutztemperatur
address: 1098
unit_of_measurement: "°C"
value_type: S_WORD
@@ -160,7 +160,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk3_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
id: ${name}_HK3_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
id: ${lower_name}_HK3_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1105
unit_of_measurement: "°C"
value_type: S_WORD

View File

@@ -2,7 +2,7 @@ select:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Betriebsart"
id: ${name}_HK4_Betriebsart
id: ${lower_name}_HK4_Betriebsart
address: 8049
value_type: U_WORD
optionsmap:
@@ -17,7 +17,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Vorlauf-Isttemperatur"
id: ${name}_HK4_Vorlauf_Isttemperatur
id: ${lower_name}_HK4_Vorlauf_Isttemperatur
register_type: read
address: 1120 #Wrong ?
unit_of_measurement: "°C"
@@ -28,7 +28,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Vorlauf-Solltemperatur"
id: ${name}_HK4_Vorlauf_Solltemperatur
id: ${lower_name}_HK4_Vorlauf_Solltemperatur
register_type: read
address: 1121 #Wrong ?
unit_of_measurement: "°C"
@@ -39,7 +39,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Raumtemperatur"
id: ${name}_HK4_Raumtemperatur
id: ${lower_name}_HK4_Raumtemperatur
register_type: read
address: 1122 #Wrong ?
unit_of_measurement: "°C"
@@ -51,7 +51,7 @@ binary_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Pumpe AN AUS"
id: ${name}_HK4_Pumpe_AN_AUS
id: ${lower_name}_HK4_Pumpe_AN_AUS
register_type: coil
address: 1120
@@ -60,7 +60,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
id: ${name}_HK4_Vorlauf_Temperatur_10C_Aussentemperatur
id: ${lower_name}_HK4_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1121
unit_of_measurement: "°C"
value_type: S_WORD
@@ -72,7 +72,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
id: ${name}_HK4_Vorlauf_Temperatur_minus_10C_Aussentemperatur
id: ${lower_name}_HK4_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1122
unit_of_measurement: "°C"
value_type: S_WORD
@@ -83,7 +83,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
id: ${name}_HK4_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
id: ${lower_name}_HK4_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1123
unit_of_measurement: "°C"
value_type: S_WORD
@@ -94,7 +94,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
id: ${name}_HK4_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
id: ${lower_name}_HK4_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1129
unit_of_measurement: "°C"
value_type: S_WORD
@@ -105,7 +105,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
id: ${name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1125
unit_of_measurement: "°C"
value_type: S_WORD
@@ -116,7 +116,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
id: ${name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
id: ${lower_name}_HK4_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1130
unit_of_measurement: "°C"
value_type: S_WORD
@@ -127,7 +127,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
id: ${name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1126
unit_of_measurement: "°C"
value_type: S_WORD
@@ -138,7 +138,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
id: ${name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
id: ${lower_name}_HK4_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1127
unit_of_measurement: "°C"
value_type: S_WORD
@@ -149,7 +149,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Frostschutztemperatur"
id: ${name}_HK4_Frostschutztemperatur
id: ${lower_name}_HK4_Frostschutztemperatur
address: 1128
unit_of_measurement: "°C"
value_type: S_WORD
@@ -160,7 +160,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk4_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
id: ${name}_HK4_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
id: ${lower_name}_HK4_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1135
unit_of_measurement: "°C"
value_type: S_WORD

View File

@@ -2,7 +2,7 @@ select:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Betriebsart"
id: ${name}_HK5_Betriebsart
id: ${lower_name}_HK5_Betriebsart
address: 8050
value_type: U_WORD
optionsmap:
@@ -17,7 +17,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Vorlauf-Isttemperatur"
id: ${name}_HK5_Vorlauf_Isttemperatur
id: ${lower_name}_HK5_Vorlauf_Isttemperatur
register_type: read
address: 1150 #Wrong ?
unit_of_measurement: "°C"
@@ -28,7 +28,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Vorlauf-Solltemperatur"
id: ${name}_HK5_Vorlauf_Solltemperatur
id: ${lower_name}_HK5_Vorlauf_Solltemperatur
register_type: read
address: 1151 #Wrong ?
unit_of_measurement: "°C"
@@ -39,7 +39,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Raumtemperatur"
id: ${name}_HK5_Raumtemperatur
id: ${lower_name}_HK5_Raumtemperatur
register_type: read
address: 1152 #Wrong ?
unit_of_measurement: "°C"
@@ -51,7 +51,7 @@ binary_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Pumpe AN AUS"
id: ${name}_HK5_Pumpe_AN_AUS
id: ${lower_name}_HK5_Pumpe_AN_AUS
register_type: coil
address: 1150
@@ -60,7 +60,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Gewünschte Vorlauf-temperatur bei +10°C Außentemperatur"
id: ${name}_HK5_Vorlauf_Temperatur_10C_Aussentemperatur
id: ${lower_name}_HK5_Vorlauf_Temperatur_10C_Aussentemperatur
address: 1151
unit_of_measurement: "°C"
value_type: S_WORD
@@ -72,7 +72,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Gewünschte Vorlauf-temperatur bei -10°C Außentemperatur"
id: ${name}_HK5_Vorlauf_Temperatur_minus_10C_Aussentemperatur
id: ${lower_name}_HK5_Vorlauf_Temperatur_minus_10C_Aussentemperatur
address: 1152
unit_of_measurement: "°C"
value_type: S_WORD
@@ -83,7 +83,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Absenkung der Vorlauftemperatur im Absenkbetrieb"
id: ${name}_HK5_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
id: ${lower_name}_HK5_Absenkung_der_Vorlauftemperatur_im_Absenkbetrieb
address: 1153
unit_of_measurement: "°C"
value_type: S_WORD
@@ -94,7 +94,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Heizkreispumpe ausschalten wenn Vorlauf Soll kleiner ist als"
id: ${name}_HK5_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
id: ${lower_name}_HK5_Heizkreispumpe_ausschalten_wenn_Vorlauf_Soll_kleiner_ist_als
address: 1159
unit_of_measurement: "°C"
value_type: S_WORD
@@ -105,7 +105,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Gewünschte Raumtemperatur während des Heizbetriebs"
id: ${name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
id: ${lower_name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Heizbetriebs
address: 1155
unit_of_measurement: "°C"
value_type: S_WORD
@@ -116,7 +116,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Gewünschte Raumtemperatur während des Absenkbetriebes"
id: ${name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
id: ${lower_name}_HK5_Gewuenschte_Raumtemperatur_waehrend_des_Absenkbetriebes
address: 1160
unit_of_measurement: "°C"
value_type: S_WORD
@@ -127,7 +127,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Außentemperatur, unter der die Heizkreispumpe im Heizbetrieb einschaltet"
id: ${name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
id: ${lower_name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Heizbetrieb_einschaltet
address: 1156
unit_of_measurement: "°C"
value_type: S_WORD
@@ -138,7 +138,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Außentemperatur, unter der die Heizkreispumpe im Absenkbetrieb einschaltet"
id: ${name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
id: ${lower_name}_HK5_Aussentemperatur_unter_der_die_Heizkreispumpe_im_Absenkbetrieb_einschaltet
address: 1157
unit_of_measurement: "°C"
value_type: S_WORD
@@ -149,7 +149,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Frostschutztemperatur"
id: ${name}_HK5_Frostschutztemperatur
id: ${lower_name}_HK5_Frostschutztemperatur
address: 1158
unit_of_measurement: "°C"
value_type: S_WORD
@@ -160,7 +160,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${hk5_name} - Temp. am Puffer oben ab der der Überhitzungsschutz aktiv wird"
id: ${name}_HK5_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
id: ${lower_name}_HK5_Temp_am_Puffer_oben_ab_der_der_Ueberhitzungsschutz_aktiv_wird
address: 1165
unit_of_measurement: "°C"
value_type: S_WORD

View File

@@ -2,7 +2,7 @@ text_sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Kesselzustand"
id: ${name}_Kesselzustand
id: ${lower_name}_Kesselzustand
register_type: read
address: 4001
raw_encode: HEXBYTES
@@ -100,7 +100,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Kesseltemperatur"
id: ${name}_Kesseltemperatur
id: ${lower_name}_Kesseltemperatur
register_type: read
address: 0
unit_of_measurement: "°C"
@@ -111,7 +111,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Abgastemperatur"
id: ${name}_Abgastemperatur
id: ${lower_name}_Abgastemperatur
register_type: read
address: 1
unit_of_measurement: "°C"
@@ -120,7 +120,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Saugzug - Ansteuerung"
id: ${name}_Saugzug_Ansteuerung
id: ${lower_name}_Saugzug_Ansteuerung
register_type: read
address: 13
unit_of_measurement: "%"
@@ -129,7 +129,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Saugzugdrehzahl"
id: ${name}_Saugzugdrehzahl
id: ${lower_name}_Saugzugdrehzahl
register_type: read
address: 6
unit_of_measurement: "rpm"
@@ -138,7 +138,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Sauerstoffregler"
id: ${name}_Sauerstoffregler
id: ${lower_name}_Sauerstoffregler
register_type: read
address: 16
unit_of_measurement: "%"
@@ -147,7 +147,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Restsauerstoffgehalt"
id: ${name}_Restsauerstoffgehalt
id: ${lower_name}_Restsauerstoffgehalt
register_type: read
address: 3
unit_of_measurement: "%"
@@ -159,7 +159,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Rücklauffühler"
id: ${name}_Ruecklauffuehler
id: ${lower_name}_Ruecklauffuehler
register_type: read
address: 9
unit_of_measurement: "°C"
@@ -170,7 +170,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Primärluft"
id: ${name}_Primaerluft
id: ${lower_name}_Primaerluft
register_type: read
address: 11
unit_of_measurement: "%"
@@ -179,7 +179,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Sekundärluft"
id: ${name}_Sekundaerluft
id: ${lower_name}_Sekundaerluft
register_type: read
address: 12
unit_of_measurement: "%"
@@ -188,7 +188,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Kesselstellgröße"
id: ${name}_Kesselstellgroesse
id: ${lower_name}_Kesselstellgroesse
register_type: read
address: 14
unit_of_measurement: "%"
@@ -197,7 +197,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Betriebsstunden"
id: ${name}_Betriebsstunden
id: ${lower_name}_Betriebsstunden
register_type: read
address: 20
unit_of_measurement: "h"
@@ -206,7 +206,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Anzahl der Brennerstarts"
id: ${name}_Anzahl_der_Brennerstarts
id: ${lower_name}_Anzahl_der_Brennerstarts
register_type: read
address: 22
value_type: U_WORD
@@ -214,7 +214,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Betriebsstunden in der Feuererhaltung"
id: ${name}_Betriebsstunden_in_der_Feuererhaltung
id: ${lower_name}_Betriebsstunden_in_der_Feuererhaltung
register_type: read
address: 24
unit_of_measurement: "h"
@@ -223,7 +223,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Errechnete Kesselsolltemperatur"
id: ${name}_Errechnete_Kesselsolltemperatur
id: ${lower_name}_Errechnete_Kesselsolltemperatur
register_type: read
address: 27
unit_of_measurement: "°C"
@@ -234,7 +234,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Stunden seit letzter Wartung"
id: ${name}_Stunden_seit_letzter_Wartung
id: ${lower_name}_Stunden_seit_letzter_Wartung
register_type: read
address: 55
unit_of_measurement: "h"
@@ -243,7 +243,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Verbleibende Heizstunden bis zur Asche entleeren Warnung"
id: ${name}_Verbleibende_Heizstunden_bis_zur_Asche_entleeren_Warnung
id: ${lower_name}_Verbleibende_Heizstunden_bis_zur_Asche_entleeren_Warnung
register_type: read
address: 86
unit_of_measurement: "h"
@@ -252,7 +252,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Aussentemperatur"
id: ${name}_Aussentemperatur
id: ${lower_name}_Aussentemperatur
register_type: read
address: 1000
unit_of_measurement: "°C"
@@ -263,9 +263,9 @@ sensor:
binary_sensor:
- platform: template
name: "${name} Kesselzustand Heizen"
id: ${name}_Kesselzustand_Heizen
id: ${lower_name}_Kesselzustand_Heizen
lambda: |-
if (id(${name}_Kesselzustand).state == "Heizen") {
if (id(${lower_name}_Kesselzustand).state == "Heizen") {
return true;
} else {
return false;
@@ -275,7 +275,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Kessel-Solltemperatur"
id: ${name}_Kessel_Solltemperatur
id: ${lower_name}_Kessel_Solltemperatur
address: 0
unit_of_measurement: "°C"
value_type: U_WORD

View File

@@ -2,7 +2,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Drehzahl Netzpumpe"
id: ${name}_Drehzahl_Netzpumpe
id: ${lower_name}_Drehzahl_Netzpumpe
register_type: read
address: 700
unit_of_measurement: "%"
@@ -11,7 +11,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Netzrücklauf Temperatur"
id: ${name}_Netzruecklauf_Temperatur
id: ${lower_name}_Netzruecklauf_Temperatur
register_type: read
address: 701
unit_of_measurement: "°C"
@@ -22,9 +22,9 @@ sensor:
binary_sensor:
- platform: template
name: "${name} Netzpumpe AN AUS"
id: ${name}_Netzpumpe_AN_AUS
id: ${lower_name}_Netzpumpe_AN_AUS
lambda: |-
if (id(${name}_Drehzahl_Netzpumpe).state > 0) {
if (id(${lower_name}_Drehzahl_Netzpumpe).state > 0) {
return true;
} else {
return false;

View File

@@ -2,7 +2,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${puffer1_name} Temperatur oben"
id: ${name}_Puffer_1_Temperatur_oben
id: ${lower_name}_Puffer_1_Temperatur_oben
register_type: read
address: 2000
unit_of_measurement: "°C"
@@ -13,7 +13,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${puffer1_name} Temperatur mitte"
id: ${name}_Puffer_1_Temperatur_mitte
id: ${lower_name}_Puffer_1_Temperatur_mitte
register_type: read
address: 2001
unit_of_measurement: "°C"
@@ -24,7 +24,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${puffer1_name} Temperatur unten"
id: ${name}_Puffer_1_Temperatur_unten
id: ${lower_name}_Puffer_1_Temperatur_unten
register_type: read
address: 2002
unit_of_measurement: "°C"
@@ -35,7 +35,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${puffer1_name} Ladezustand"
id: ${name}_Puffer_1_Ladezustand
id: ${lower_name}_Puffer_1_Ladezustand
register_type: read
address: 2006
unit_of_measurement: "%"
@@ -44,7 +44,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${puffer1_name} Pufferpumpen Ansteuerung"
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung
id: ${lower_name}_Puffer_1_Pufferpumpen_Ansteuerung
register_type: read
address: 2003
unit_of_measurement: "%"
@@ -53,9 +53,9 @@ sensor:
binary_sensor:
- platform: template
name: "${puffer1_name} Pufferpumpen Ansteuerung AN AUS"
id: ${name}_Puffer_1_Pufferpumpen_Ansteuerung_AN_AUS
id: ${lower_name}_Puffer_1_Pufferpumpen_Ansteuerung_AN_AUS
lambda: |-
if (id(${name}_Puffer_1_Pufferpumpen_Ansteuerung).state > 0) {
if (id(${lower_name}_Puffer_1_Pufferpumpen_Ansteuerung).state > 0) {
return true;
} else {
return false;

View File

@@ -2,7 +2,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Ruecklauftemperatur an der Zirkulations Leitung"
id: ${name}_Ruecklauftemperatur_an_der_Zirkulations_Leitung
id: ${lower_name}_Ruecklauftemperatur_an_der_Zirkulations_Leitung
register_type: read
address: 711
unit_of_measurement: "°C"
@@ -13,7 +13,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Strömungsschalter an der Brauchwasser Leitung"
id: ${name}_Stoemungsschalter_an_der_Brauchwasser_Leitung
id: ${lower_name}_Stoemungsschalter_an_der_Brauchwasser_Leitung
register_type: read
address: 600
value_type: U_WORD
@@ -21,7 +21,7 @@ sensor:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Drehzahl der Zirkulations Pumpe"
id: ${name}_Drehzahl_der_Zirkulations_Pumpe
id: ${lower_name}_Drehzahl_der_Zirkulations_Pumpe
register_type: read
address: 710
unit_of_measurement: "%"
@@ -30,9 +30,9 @@ sensor:
binary_sensor:
- platform: template
name: "${name} Zirkulationspumpe AN AUS"
id: ${name}_Zirkulations_Pumpe_AN_AUS
id: ${lower_name}_Zirkulations_Pumpe_AN_AUS
lambda: |-
if (id(${name}_Drehzahl_der_Zirkulations_Pumpe).state > 0) {
if (id(${lower_name}_Drehzahl_der_Zirkulations_Pumpe).state > 0) {
return true;
} else {
return false;
@@ -42,7 +42,7 @@ number:
- platform: modbus_controller
modbus_controller_id: ${modbus_controller_id}
name: "${name} Bei welcher RL Temperatur an der Zirkulationsleitung soll die Pumpe ausschalten"
id: ${name}_Bei_welcher_RL_Temperatur_an_der_Zirkulationsleitung_soll_die_Pumpe_ausschalten
id: ${lower_name}_Bei_welcher_RL_Temperatur_an_der_Zirkulationsleitung_soll_die_Pumpe_ausschalten
address: 600
unit_of_measurement: "°C"
value_type: U_WORD